What type of climate correction is most accurate for monitoring the thermal demand of buildings? The case of the IDC data base (Geneva)

Published inJournal of physics. Conference series, vol. 3140, no. 6, 062032
Publication date2025-11-01
Abstract

In order to track the evolution of building heat demand in relation with building retrofit and other saving measures, a specific challenge consists in applying of a proper climate correction method. In this paper, we compare the Heating Degree Days (HDD) and Accumulated Temperature Differences (ATD), as applied to actual energy metering of around 18,000 buildings, over more than a decade. We conclude that for the current building stock, there is little difference between the HDD and the ATD methods. However, as most buildings are expected to meet high energy standards in future, switching from HDD to ATD with an appropriate space heating cut-off temperature could be of interest. Finally, using a specific example at territorial level, we demonstrate that the use of daily energy demand data can facilitate the development of a highly effective climate correction model.

Keywords
  • Energy demand
  • Climate correction
  • Heating degree days
  • Accumulated temperature
  • Building efficiency
  • Heat consumption index
  • Geneva IDC database
Citation (ISO format)
SCHNEIDER, Stefan et al. What type of climate correction is most accurate for monitoring the thermal demand of buildings? The case of the IDC data base (Geneva). In: Journal of physics. Conference series, 2025, vol. 3140, n° 6, p. 062032. doi: 10.1088/1742-6596/3140/6/062032
Main files (1)
Article (Published version)
Identifiers
Journal ISSN1742-6588
65views
158downloads

Technical informations

Creation15/12/2025 13:37:29
First validation17/12/2025 13:40:17
Update17/12/2025 13:40:17
Status update17/12/2025 13:40:17
Last indexation17/12/2025 13:40:18
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack