CO2 emission savings of heat-pumps in the residential sector. Case study for multifamily buildings in Geneva

Presented at Jeju (Korea), May 11-14
Publication date2020
Abstract

The present paper assesses the CO2 emissions of air-source and groundwater-source HP systems, with and without complementary PV, for a sample of multifamily buildings (new, retrofitted and non-retrofitted) located in Geneva. HP performance is evaluated by way of numerical simulation in hourly time step, and is cross-cut with the hourly grid CO2 content of the Swiss electricity mix (taking into account both domestic generation and imports from the neighbor countries). Given the seasonal trend of both the building heat demand and the grid CO2 content, latter turns out to strongly underestimate the CO2 content of the HP system electricity. Nonetheless, when compared with a gas boiler, both HP systems induce important annual CO2 savings (air: 61 - 81% depending on the accounting method; groundwater: 75% - 87%). Finally, while PV can substantially contribute to the summer HP demand, the related annual CO2 savings remain relatively marginal, also due to seasonality of the grid CO2 content.

Keywords
  • Heat pump (HP)
  • Photovoltaic (PV)
  • Multifamily building
  • CO2 emissions
Citation (ISO format)
ROMANO, Elliot, DE SOUSA FRAGA, Carolina, HOLLMULLER, Pierre. CO2 emission savings of heat-pumps in the residential sector. Case study for multifamily buildings in Geneva. In: 13th IEA Heat Pump Conference 2020. Jeju (Korea). [s.l.] : [s.n.], 2020.
Main files (1)
Proceedings chapter (Accepted version)
accessLevelPublic
Identifiers
  • PID : unige:136512
438views
152downloads

Technical informations

Creation05/28/2020 2:42:00 PM
First validation05/28/2020 2:42:00 PM
Update time03/15/2023 10:02:47 PM
Status update03/15/2023 10:02:47 PM
Last indexation05/05/2024 4:50:21 PM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack