Scientific article
English

Comparison of gel-based methods for the detection of cerebrospinal fluid rhinorrhea

Published in

Clinica chimica acta, vol. 413, no. 13-14, p. 1145-1150

Publication date

2012

Abstract

Cerebrospinal fluid (CSF) rhinorrhea is a serious condition that may result in severe complications. Various laboratory tests, relying on the detection of CSF-specific proteins in nasal secretions, have been developed but diagnosis remains challenging. The aim of this study was to evaluate two new methods targeting either ß2-transferrin or beta-trace-protein. Rhinorrhea samples from patients suspected of CSF leakage (n=36) were analyzed using two-dimensional gel electrophoresis (2-DE) for CSF rhinorrhea diagnosis. Twelve patients with rhinorrhea strongly suggestive of a CSF leak also underwent a fluorescein test. The same cohort was retrospectively analyzed with a beta-trace protein immunoblot developed in-house (n=36) and a new commercial ß2-transferrin immunofixation assay (Sebia, Evry, France) (n=33). 2-DE was positive in 9 patients suffering from rhinorrhea following skull base fracture (n=3), post-surgery (n=4), or spontaneously (n=2). The 27 remaining cases were negative. These results were confirmed by the beta-trace protein immunoblot and ß2-transferrin immunofixation tests, except for one sample found negative with 2-DE but positive with the two other assays. Results from the three analytical methods were concordant with fluorescein tests. Beta-trace protein immunoblot and ß2-transferrin immunofixation assays are fast and reliable methods that allow detecting CSF leakage in nasal fluid with high sensitivity and specificity.

Keywords

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Cerebrospinal Fluid Rhinorrhea/diagnosis
  • Female
  • Humans
  • Immunoblotting/methods
  • Immunoelectrophoresis/methods
  • Intramolecular Oxidoreductases/analysis
  • Lipocalins/analysis
  • Male
  • Middle Aged
  • Transferrin/analysis
  • Young Adult

Citation (ISO format)

LESCUYER, Pierre et al. Comparison of gel-based methods for the detection of cerebrospinal fluid rhinorrhea. In: Clinica chimica acta, 2012, vol. 413, n° 13-14, p. 1145–1150. doi: 10.1016/j.cca.2012.03.016

Main files (1)

Article (Published version)

Identifiers

Journal ISSN

0009-8981
619views
0downloads

Technical informations

Creation

02/01/2014 16:51:00

First validation

02/01/2014 16:51:00

Update

23/01/2025 11:42:12

Status update

23/01/2025 11:42:12

Last indexation

23/01/2025 11:48:56
All rights reserved by Archive ouverte UNIGE and the University of Geneva
OpenAIRE Indexed & Validated