Screening of Illegal Intracorporeal Containers ("Body Packing"): Is Abdominal Radiography Sufficiently Accurate? A Comparative Study with Low-Dose CT

Published inRadiology, vol. 265, no. 3, p. 772-779
Publication date2012
Abstract

Purpose:To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard.Materials and Methods:This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography.Results:Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively).Conclusion:Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.©RSNA, 2012.

Citation (ISO format)
POLETTI, Pierre-Alexandre Alois et al. Screening of Illegal Intracorporeal Containers (‘Body Packing’): Is Abdominal Radiography Sufficiently Accurate? A Comparative Study with Low-Dose CT. In: Radiology, 2012, vol. 265, n° 3, p. 772–779. doi: 10.1148/radiol.12112767
Main files (1)
Article (Published version)
accessLevelPrivate
Identifiers
Journal ISSN0033-8419
726views
0downloads

Technical informations

Creation04/10/2012 11:54:00
First validation04/10/2012 11:54:00
Update14/03/2023 19:55:36
Status update14/03/2023 19:55:36
Last indexation30/10/2024 08:21:16
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack