UNIGE document Scientific Article
previous document  unige:88529  next document
add to browser collection
Title

Predictors of Heavy Stethoscope Contamination Following a Physical Examination

Authors
Tschopp, Clément
Schneider, Alexis
Longtin, Yves
Renzi, Gesuele
Published in Infection Control and Hospital Epidemiology. 2016, vol. 37, no. 6, p. 673-679
Abstract BACKGROUND The degree of bacterial contamination of stethoscopes can vary significantly following a physical examination. OBJECTIVE To conduct a prospective study to investigate the impact of various environmental and patient characteristics on stethoscope contamination. METHODS Following a standardized examination, the levels of bacterial contamination of 4 regions of the physicians' hands and 2 sections of the stethoscopes, and the presence of different pathogenic bacteria, were assessed. Predictors of heavy stethoscope contamination were identified through multivariate logistic regression. RESULTS In total, 392 surfaces were sampled following examination of 56 patients. The microorganisms most frequently recovered from hands and stethoscopes were Enterococcus spp. (29% and 20%, respectively) and Enterobacteriaceae (16% and 7%, respectively). Staphylococcus aureus (either methicillin susceptible or resistant), extended-spectrum β-lactamase-producing Enterobacteriaceae, and Acinetobacter baumannii were recovered from 4%-9% of the samples from either hands or stethoscopes. There was a correlation between the likelihood of recovering these pathogens from the stethoscopes vs from the physicians' hands (ρ=0.79; P=.04). The level of patient's skin contamination was an independent predictor of contamination of the stethoscope diaphragm (adjusted odds ratio [aOR], 1.001; P=.007) and tube (aOR, 1.001; P=.003). Male sex (aOR, 28.24; P=.01) and reception of a bed bath (aOR, 7.52; P=.048) were also independently associated with heavy tube contamination. CONCLUSIONS Stethoscope contamination following a single physical examination is not negligible and is associated with the level of contamination of the patient's skin. Prevention of pathogen dissemination is needed. Infect Control Hosp Epidemiol 2016;37:673-679.
Identifiers
PMID: 27198604
Full text
Article (Published version) (234 Kb) - document accessible for UNIGE members only Limited access to UNIGE
Structures
Research group Staphylocoques dorés résistants à la méthicilline et hygiène hospitalière (330)
Citation
(ISO format)
TSCHOPP, Clément et al. Predictors of Heavy Stethoscope Contamination Following a Physical Examination. In: Infection Control and Hospital Epidemiology, 2016, vol. 37, n° 6, p. 673-679. https://archive-ouverte.unige.ch/unige:88529

47 hits

0 download

Update

Deposited on : 2016-11-01

Export document
Format :
Citation style :