Enhanced method performances for conventional and chiral CE-ESI/MS analyses in plasma

Published in

Electrophoresis, vol. 27, no. 8, p. 1537-1546

Publication date

2006

Abstract

Due to its high efficiency, selectivity, and sensitivity, CE-ESI/MS has evolved as an efficient technique for the drugs and metabolites analysis in biological matrices. However, a sample preparation is mandatory prior to CE-ESI/MS analysis. To achieve fast and simplified sample preparation of plasma samples, protein precipitation (PP) and liquid-liquid extraction (LLE) were used with two injection techniques: hydrodynamic (HD) and electrokinetic (EK) injection. CE-ESI/MS analyses of pharmaceutical compounds and amphetamine derivatives were developed. Detection limits of 1 ppm were reached with PP and HD injection whereas 1 ppb was detected when samples were prepared with LLE and injected by EK. Same experiments were performed for stereoselective determinations in partial-filling mode and detection limits achieved were equivalent to conventional analysis (0.5 ppb per enantiomer). When complex matrices are analyzed, MS signal suppression or enhancement effects are generally not reproducible and could compromise results with ESI. Therefore, matrix effect was investigated in CE-ESI/MS with a commercially available coaxial sheath-liquid ESI interface used as postcapillary infusion system to determine MS signal alterations. Matrix effects were differentially evidenced according to the selected sample preparation. With PP, signal suppression was observed out of the analyses migration window, while for LLE no relevant matrix effect occurred in all experiments.

Keywords

  • Amphetamines/blood/isolation & purification
  • Electrophoresis, Capillary/instrumentation/methods
  • Methadone/blood
  • Pharmaceutical Preparations/blood
  • Spectrometry, Mass, Electrospray Ionization/instrumentation/methods
  • Stereoisomerism
  • Tramadol/blood
  • Gamma-Cyclodextrins

Citation (ISO format)

SCHAPPLER, Julie et al. Enhanced method performances for conventional and chiral CE-ESI/MS analyses in plasma. In: Electrophoresis, 2006, vol. 27, n° 8, p. 1537–1546. doi: 10.1002/elps.200500805

Main files (1)

Article (Published version)

Identifiers

Journal ISSN

0173-0835
649views
3downloads

Technical informations

Creation

21/05/2010 11:18:00

First validation

21/05/2010 11:18:00

Update

14/03/2023 15:29:14

Status update

14/03/2023 15:29:14

Last indexation

18/03/2025 09:19:01
All rights reserved by Archive ouverte UNIGE and the University of Geneva
OpenAIRE Indexed & Validated