Evaluation of S-values and dose distributions for (90)Y, (131)I, (166)Ho, and (188)Re in seven lobes of the rat liver

Published inMedical physics, vol. 39, no. 3, p. 1462-1472
Publication date2012
Abstract

Rats have been widely used in radionuclide therapy research for the treatment of hepatocellular carcinoma (HCC). This has created the need to assess rat liver absorbed radiation dose. In most dose estimation studies, the rat liver is considered as a homogeneous integrated target organ with a tissue composition assumed to be similar to that of human liver tissue. However, the rat liver is composed of several lobes having different anatomical and chemical characteristics. To assess the overall impact on rat liver dose calculation, the authors use a new voxel-based rat model with identified suborgan regions of the liver.

Keywords
  • Animals
  • Carcinoma, Hepatocellular/radiotherapy
  • Electrons
  • Holmium/therapeutic use
  • Iodine Radioisotopes/therapeutic use
  • Liver/radiation effects
  • Liver Neoplasms/radiotherapy
  • Monte Carlo Method
  • Photons/therapeutic use
  • Radiation Dosage
  • Rats
  • Rats, Sprague-Dawley
  • Rhenium/therapeutic use
  • Yttrium Radioisotopes/therapeutic use
Funding
  • Swiss National Science Foundation - 31003A-135576
Citation (ISO format)
XIE, Tianwu, LIU, Qian, ZAIDI, Habib. Evaluation of S-values and dose distributions for (90)Y, (131)I, (166)Ho, and (188)Re in seven lobes of the rat liver. In: Medical physics, 2012, vol. 39, n° 3, p. 1462–1472. doi: 10.1118/1.3681009
Main files (1)
Article (Published version)
accessLevelPublic
Identifiers
Journal ISSN0094-2405
594views
453downloads

Technical informations

Creation29/10/2013 11:21:00
First validation29/10/2013 11:21:00
Update time14/03/2023 20:35:16
Status update14/03/2023 20:35:16
Last indexation30/10/2024 14:49:25
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack