Scientific article
OA Policy
English

Validity of accelerometer-based analysis of step time and step time variability during treadmill walking in people with bilateral vestibulopathy

Published inGait & posture, vol. 123, 110016
Publication date2026-01
First online date2025-10-17
Abstract

Background: Gait and balance impairments, including increased gait variability, are prevalent in people with bilateral vestibulopathy (BVP). Wearable accelerometers may provide a clinically feasible method to objectively assess gait variability but have not yet been explored in BVP.

Research question: Is accelerometer-based assessment of step time variability during treadmill walking valid in people with BVP?

Methods: Adults with BVP and age-sex-matched healthy controls walked at 0.6 m/s, 0.8 m/s, and 1.0 m/s on the treadmill of the Computer Assisted Rehabilitation Environment. We examined differences in step time means and coefficients of variation (CoV) between accelerometery (single lower back sensor; MOX1) and 3D motion capture and force plates (Vicon). Validity was assessed using intraclass correlation coefficients (ICC3,1), Pearson and Spearman correlation coefficients, and Bland-Altman analyses to determine agreement, association and consistency between the methods. Validity was additionally assessed by comparing statistical significant differences and the effect sizes between the groups using each method.

Results: Mean step time showed moderate to excellent agreement between methods, while step time CoV showed poor agreement and proportional bias. Accelerometery showed consistent between-group significance and effect size values, particularly at 0.6 m/s, although effect sizes were larger in motion capture data than in accelerometer data.

Significance: An accelerometer-based assessment is valid for assessing mean step time in people with BVP. For assessing step time variability, it can distinguish between known groups (particularly at slower speeds) but does not demonstrate criterion validity. Before clinical application, test-retest reliability and sensitivity to change should be assessed in BVP.

Keywords
  • Gait
  • Motion capture
  • Sensor
  • Vestibular hypofunction
Citation (ISO format)
ZHU, Meichan et al. Validity of accelerometer-based analysis of step time and step time variability during treadmill walking in people with bilateral vestibulopathy. In: Gait & posture, 2026, vol. 123, p. 110016. doi: 10.1016/j.gaitpost.2025.110016
Main files (1)
Article (Published version)
Identifiers
Journal ISSN0966-6362
20views
35downloads

Technical informations

Creation22/10/2025 14:49:46
First validation04/12/2025 09:20:24
Update04/12/2025 09:20:24
Status update04/12/2025 09:20:24
Last indexation04/12/2025 09:20:25
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack