Scientific article
English

Trueness and Passivity of Digital and Conventional Implant Impressions in Edentulous Jaws : A Prospective Clinical Study

Published inClinical implant dentistry and related research, vol. 27, no. 2, e70022
Publication date2025-04
First online date2025-04-08
Abstract

Aim: To compare the linear and angular deviations of conventional implant (CI) and digital implant (DI) impression techniques in edentulous jaws with four or six implants.

Materials and methods: Twenty participants (12 men, 8 women; mean age 58.6 years) with complete edentulous maxillary (n = 8) or mandibular (n = 12) arches were included. Each patient received four or six dental implants (Straumann BLX). Both CI and DI were performed using randomized sequences. Linear and angular deviations were measured between the reference scan (coordinated measuring machine) and the CI (desktop scanner) and DI (intraoral scanner, IOS) using CATIA software (Dassault Systèmes). Framework passivity was evaluated using the Sheffield one-screw test. The Shapiro-Wilk test determined data normality (p < 0.05), and nonparametric statistical tests were applied using statistical software.

Results: Descriptive statistics showed a mean linear discrepancy of 29.05 (84.80 μm) for CI and 6.95 (154.10 μm) for DI, with angular deviations of 0.06° (0.36°) for CI and 0.05° (1.40°) for DI. No statistically significant differences were found in linear (p = 0.38) or angular (p = 0.12) measurements between CI and DI. Framework passivity testing showed that both techniques achieved passive fit in 17 out of 20 cases (85%), with the reference scan achieving passivity in 18 (90%) cases. Distal implants, particularly in the upper jaw, exhibited greater discrepancies, but none were statistically significant.

Conclusions: No significant differences in trueness were found between CI and DI techniques. Both methods demonstrated comparable trueness and framework passivity, supporting the use of IOS as a reliable alternative to CI in edentulous jaws with multiple implants.

Keywords
  • Accuracy
  • Conventional impressions
  • Digital impressions
  • Framework passivity
  • Implant dentistry
Citation (ISO format)
HARFAGAR, Gustavo et al. Trueness and Passivity of Digital and Conventional Implant Impressions in Edentulous Jaws : A Prospective Clinical Study. In: Clinical implant dentistry and related research, 2025, vol. 27, n° 2, p. e70022. doi: 10.1111/cid.70022
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN1523-0899
33views
0downloads

Technical informations

Creation16/07/2025 14:39:55
First validation21/07/2025 10:12:56
Update21/07/2025 10:12:56
Status update21/07/2025 10:12:56
Last indexation21/07/2025 10:12:57
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack