Scientific article
English

Intraoperative contrast-enhanced cone beam CT allows visualization of the 'dark side' of the clot and improves mechanical thrombectomy performance

Published inJournal of neurointerventional surgery, vol. 17, no. e2, p. e333-e339
Publication date2025-05
First online date2024-10-22
Abstract

Background: Visualization of the clot is key to the endovascular treatment of ischemic stroke, but identification of the distal part of the clot and distal arteries during mechanical thrombectomy (MT) remains challenging with conventional intraoperative imaging. We aimed to leverage the potential of contrast-enhanced cone beam CT (CE-CBCT) to better visualize the distality ('dark side') of the clot.

Methods: We retrospectively analyzed all patients treated with MT for medium vessel occlusion (MeVO) guided by three-dimensional (3D) imaging to identify those who underwent either CE-CBCT or 3D rotational angiography (3DRA). Our primary outcome was the visualization of the proximal and distal edges of the clot and the arteries beyond the occlusion on the different types of intraoperative imaging: digital subtraction angiography (DSA), 3DRA, and CE-CBCT. Secondary outcomes included the efficacy, safety, and timing of MT between CE-CBCT versus 3DRA groups.

Results: The proximal edge of the clot was well visualized by DSA, 3DRA, and CE-CBCT. However, the distal edge of the clot and distal arteries were significantly better visualized with CE-CBCT (60.0%) than 3DRA (2.7%) and DSA (11.4-13.5%). Moreover, MT efficacy was better with CE-CBCT than 3DRA, with higher first-pass effect (65.7% vs 37.8%) and final recanalization grade (expanded Treatment In Cerebral Infarction (eTICI) 3: 71.4% vs 43.2%). Finally, the visualization of the distal edge of the clot and distal arteries correlated with better collateralization grade.

Conclusion: CE-CBCT localizes the clot and reveals the underlying vascular anatomy better than 3DRA or DSA, thereby enhancing the efficacy of MT. The improved filling of collaterals with CE-CBCT may explain this better visualization of the 'dark side' of the clot.

Keywords
  • Angiography
  • Intervention
  • Stroke
  • Technique
  • Thrombectomy
Citation (ISO format)
HOFMEISTER, Jérémy et al. Intraoperative contrast-enhanced cone beam CT allows visualization of the “dark side” of the clot and improves mechanical thrombectomy performance. In: Journal of neurointerventional surgery, 2025, vol. 17, n° e2, p. e333–e339. doi: 10.1136/jnis-2024-022409
Main files (1)
Article (Published version)
accessLevelRestricted
Secondary files (1)
Supplemental data
accessLevelRestricted
Identifiers
Additional URL for this publicationhttps://jnis.bmj.com/content/17/e2/e333.long
Journal ISSN1759-8478
38views
0downloads

Technical informations

Creation22/01/2025 08:54:30
First validation02/07/2025 07:53:36
Update02/07/2025 07:53:36
Status update02/07/2025 07:53:36
Last indexation18/09/2025 14:58:04
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack