| A novel method for brain aneurysms computed fluid dynamics analysis after flow diverter stent implantation based on micro-computed tomography reconstruction | Journal of biomechanics |  | | 2025 | 51 | 68 |
|
| Intraoperative contrast-enhanced cone beam CT allows visualization of the 'dark side' of the clot and improves mechanical thrombectomy performance | Journal of neurointerventional surgery |  | | 2025 | 39 | 0 |
|
| Double stent-retriever technique for mechanical thrombectomy : a systematic review and meta-analysis | American journal of neuroradiology |  | | 2024 | 159 | 6 |
|
| Experimental comparison of first-pass effect between direct thromboaspiration and combined thrombectomy in the setting of distal basilar occlusion | Interventional neuroradiology |  | | 2024 | 62 | 91 |
|
| Can micro-guidewire advancement forces predict clot consistency and location to assist the first-line technique for mechanical thrombectomy ? | Journal of neurointerventional surgery |  | | 2024 | 119 | 144 |
|
| Experimental evaluation of the performance of large bore aspiration catheters | Journal of neuroradiology |  | | 2023 | 88 | 222 |
|
| Benchtop evaluation of a double stent retriever thrombectomy technique for acute ischemic stroke treatment | Interventional neuroradiology |  | | 2023 | 116 | 208 |
|
| Spatial heterogeneity of occlusive thrombus in acute ischemic stroke: A systematic review | Journal of neuroradiology |  | | 2023 | 153 | 401 |
|
| Endovascular treatment strategies for simultaneous bilateral anterior circulation occlusions in acute ischemic stroke: A single-center experience and systematic review of the literature | Interventional neuroradiology |  | | 2023 | 128 | 213 |
|
| Three-dimensional rotational angiography improves mechanical thrombectomy recanalization rate for acute ischaemic stroke due to middle cerebral artery M2 segment occlusions | Interventional neuroradiology |  | | 2022 | 194 | 141 |
|
| MicroCT Can Characterize Clots Retrieved With Mechanical Thrombectomy From Acute Ischemic Stroke Patients – A Preliminary Report | Frontiers in neurology |  | | 2022 | 308 | 107 |
|
| In vitro evaluation of how the presence of the stent retriever and microcatheter influences aspiration parameters in thrombectomy according to their position inside the aspiration catheter | Interventional neuroradiology |  | | 2022 | 194 | 172 |
|
| Experimental evaluation of direct thromboaspiration efficacy according to the angle of interaction between the aspiration catheter and the clot | Journal of NeuroInterventional Surgery |  | | 2021 | 340 | 288 |
|
| Acute Stenting and Concomitant Tirofiban Administration for the Endovascular Treatment of Acute Ischemic Stroke Related to Intracranial Artery Dissections: A Single Center Experience and Systematic Review of the Literature | Journal of Stroke and Cerebrovascular Diseases |  | | 2021 | 285 | 201 |
|
| Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter | American Journal of Neuroradiology |  | | 2020 | 492 | 332 |
|
| Direct thromboaspiration efficacy for mechanical thrombectomy is related to the angle of interaction between the aspiration catheter and the clot | Journal of NeuroInterventional Surgery |  | | 2020 | 441 | 417 |
|
| How patient-specific do internal carotid artery inflow rates need to be for computational fluid dynamics of cerebral aneurysms? | Journal of NeuroInterventional Surgery |  | | 2020 | 295 | 0 |
|
| Robust cerebrovascular blood velocity and flow rate estimation from 4D CTA | Medical Physics |  | | 2019 | 419 | 1 |
|
| How flow reduction influences the intracranial aneurysm occlusion: a prospective 4D phase-contrast MRI study | American Journal of Neuroradiology |  | | 2019 | 475 | 360 |
|
| 4D-CT angiography versus 3D-rotational angiography as the imaging modality for computational fluid dynamics of cerebral aneurysms | Journal of NeuroInterventional Surgery |  | | 2019 | 462 | 0 |
|
| Neurovascular stent artifacts in 3D-TOF and 3D-PCMRI: Influence of stent design on flow measurement | Magnetic Resonance in Medicine |  | | 2018 | 551 | 2 |
|
| Errors in power-law estimations of inflow rates for intracranial aneurysm CFD | Journal of Biomechanics |  | | 2018 | 475 | 0 |
|
| Experimental evaluation of the NeVa™ thrombectomy device a novel stent retriever conceived to improve efficacy of organized clot removal | Journal of Neuroradiology | | | 2018 | 567 | 0 |
|
| 3D phase contrast MRI: Partial volume correction for robust blood flow quantification in small intracranial vessels | Magnetic Resonance in Medicine |  | | 2018 | 756 | 9 |
|
| Hemodynamics of Focal Versus Global Growth of Small Cerebral Aneurysms | Clinical Neuroradiology |  | | 2017 | 504 | 1 |
|
| Vessel calibre and flow splitting relationships at the internal carotid artery terminal bifurcation | Physiological Measurement |  | | 2017 | 616 | 496 |
|
| 4D Flow MRI in Neuroradiology: Techniques and Applications | Topics in Magnetic Resonance Imaging |  | | 2016 | 471 | 3 |
|
| Improving workflows of neuro-interventional procedures with autostereoscopic 3D visualization of multi-modality imaging in hybrid interventional suites | International journal of computer assisted radiology and surgery |  | | 2016 | 612 | 1 |
|
| Geometrical deployment for braided stent | Medical image analysis |  | | 2016 | 483 | 1 |
|
| Computational fluid dynamics analysis of flow reduction induced by flow-diverting stents in intracranial aneurysms: a patient-unspecific hemodynamics change perspective | Journal of neurointerventional surgery |  | | 2016 | 564 | 0 |
|
| Virtual-versus-Real Implantation of Flow Diverters: Clinical Potential and Influence of Vascular Geometry | American Journal of Neuroradiology |  | | 2016 | 445 | 224 |
|
| Computational fluid dynamics with stents: quantitative comparison with particle image velocimetry for three commercial off the shelf intracranial stents | Journal of neurointerventional surgery |  | | 2016 | 550 | 1 |
|
| Intra-aneurysmal hemodynamics: evaluation of pCONus and pCANvas bifurcation aneurysm devices using DSA optical flow imaging | Journal of neurointerventional surgery |  | | 2016 | 486 | 0 |
|
| Assessment of intra-aneurysmal flow modification after flow diverter stent placement with four-dimensional flow MRI: a feasibility study | Journal of neurointerventional surgery |  | | 2015 | 516 | 2 |
|
| Hemodynamic transition driven by stent porosity in sidewall aneurysms | Journal of biomechanics |  | | 2015 | 515 | 0 |
|
| Intra-aneurysmal flow patterns: illustrative comparison among digital subtraction angiography, optical flow, and computational fluid dynamics | American journal of neuroradiology |  | | 2014 | 564 | 269 |
|
| Wall shear stress distribution of small aneurysms prone to rupture: a case-control study | Stroke |  | | 2014 | 705 | 0 |
|
| Quantification of internal carotid artery flow with digital subtraction angiography: validation of an optical flow approach with Doppler ultrasound | American journal of neuroradiology |  | | 2014 | 672 | 1 |
|
| Multi-time-lag PIV analysis of steady and pulsatile flows in a sidewall aneurysm | Experiments in Fluids |  | | 2014 | 335 | 1 |
|
| Evaluation of the influence of inlet boundary conditions on computational fluid dynamics for intracranial aneurysms: a virtual experiment | Journal of biomechanics |  | | 2013 | 595 | 0 |
|
| Biology and hemodynamics of aneurismal vasculopathies | European journal of radiology |  | | 2013 | 579 | 0 |
|
| A DSA-based method using contrast-motion estimation for the assessment of the intra-aneurysmal flow changes induced by flow-diverter stents | American journal of neuroradiology |  | | 2013 | 716 | 2 |
|