Objective: The goal of this study was to investigate the diagnostic utility of electric source imaging (ESI) in the presurgical evaluation of children with focal cortical dysplasia (FCD) and to compare it with other imaging techniques.

Methods: Twenty patients with epilepsy onset before 18 years, surgically treated focal epilepsy with a minimal follow-up of 2 years, and histologically proven FCD were retrospectively selected. All patients underwent MRI, positron emission tomography (PET), and 16 patients also had ictal single-photon emission computed tomography (iSPECT). ESI, using EEG with 64 electrodes or more (HD-ESI), was performed in all 20 patients. We determined sensitivity, specificity and accuracy of ESI, and compared its yield to that of other imaging techniques.

Results: Twelve patients were seizure-free post-operatively (60%). Among all patients, highest localization accuracy (80%) was obtained with ESI, followed by PET and iSPECT (75%). When results from ESI and SPECT were concordant 100% of patients achieved Engel I outcome. If ESI and PET showed concordant localization, 90% of patients achieved postoperative seizure freedom.

Conclusions: Our findings demonstrate that HD-ESI allows accurate localization of the epileptogenic zone in patients with FCD.

Significance: In combination with other imaging modalities, ESI helps with planning a more accurate surgery and therefore, the chances of postoperative seizure control are higher. Since it is based on EEG recordings, it does not require sedation, which is particularly interesting in pediatric patients. ESI represents an important imaging tool in focal epilepsies due to cortical dysplasia, which might be difficult to detect on standard imaging.

Keywords
  • Children
  • Electric source imaging
  • Epilepsy surgery
  • Focal cortical dysplasia
  • Outcome
Citation (ISO format)
WANDERS, Aurélie et al. High density electric source imaging in childhood-onset epilepsy due to focal cortical dysplasia. In: Clinical neurophysiology practice, 2022, vol. 7, p. 245–251. doi: 10.1016/j.cnp.2022.07.002
Main files (1)
Article (Published version)
Identifiers
Journal ISSN2467-981X
60views
241downloads

Technical informations

Creation03/01/2023 12:48:56
First validation25/10/2024 14:53:07
Update03/12/2024 16:53:31
Status update03/12/2024 16:53:31
Last indexation03/12/2024 16:53:34
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack