Abstract

In essence, automation can be driven by several of the following incentives: increased processing capacity of the laboratory, better costs control through processes standardization, optimized traceability, or improved workflows to reduce turnaround times (TAT). This project aims at presenting an overview of the project management and change management with a focus on the major challenges addressed by lab staff and laboratory leadership during the different phases of the implementation of the WASPLab™ in a routine clinical bacteriology laboratory. This paper reports our experience and reviews changes in the bacteriology laboratory at Geneva University Hospitals when shifting to the WASPLab™. Practically, the whole automation process was segmented into different packages (specimen type-based segmentation) allowing sequential validation, staff training, and routine implementation. Such process allowed reaching 90% of the identified "automatable" samples within 1 year, including personal training, documentation for accreditation supported by publications, without interrupting routine operations. In addition, we implemented a validated automated solution for antimicrobial disk diffusion susceptibility testing. Structured supervision and accurate monitoring of all the activities related to the automation project including key partners such as IT support, technical committee, and after-sales service guaranteed a swift and timely achievement of the project allowing the improvement of the workflow in routine bacteriology within 1 year.

Keywords
  • Automation, Laboratory/standards
  • Bacteriology
  • Hospitals, University
  • Humans
  • Laboratories, Hospital/standards
  • Outcome and Process Assessment, Health Care
  • Quality Improvement
  • Switzerland
  • Workflow
Citation (ISO format)
CHERKAOUI, Abdessalam et al. Implementation of the WASPLab™ and first year achievements within a university hospital. In: European Journal of Clinical Microbiology & Infectious Diseases, 2020, vol. 39, n° 8, p. 1527–1534. doi: 10.1007/s10096-020-03872-1
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN0934-9723
268views
0downloads

Technical informations

Creation25/08/2021 12:51:00
First validation25/08/2021 12:51:00
Update time23/01/2025 11:27:05
Status update23/01/2025 11:27:05
Last indexation23/01/2025 11:35:11
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack