en
Scientific article
English

A method for fast automated assessment of the magnetic resonance parkinsonism index

Published inNeuroradiology, vol. 62, no. 6, p. 747-751
Publication date2020
Abstract

In patients with parkinsonian syndromes, and particularly during the early stages of the clinical disease, differentiating between idiopathic Parkinson's disease and progressive supranuclear palsy is challenging. Imaging plays an important role in early diagnosis, and the magnetic resonance parkinsonism index was shown to reliably differentiate between the two entities. Calculation of the index is a time-consuming process. We developed an algorithm allowing its automatic calculation based on 3D T1-weighted images, producing additional color-coded images for verification.

Keywords
  • Parkinson index
  • MRI
  • 3DT1
  • Parkinson
  • MRI
  • Automated assessment
  • Automated calculation
  • MRPI
  • PSP
  • Parkinson's disease
Citation (ISO format)
SCHEFFLER, Max et al. A method for fast automated assessment of the magnetic resonance parkinsonism index. In: Neuroradiology, 2020, vol. 62, n° 6, p. 747–751. doi: 10.1007/s00234-020-02380-5
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
ISSN of the journal0028-3940
251views
5downloads

Technical informations

Creation02/27/2020 1:08:00 PM
First validation02/27/2020 1:08:00 PM
Update time03/15/2023 9:59:05 PM
Status update03/15/2023 9:59:05 PM
Last indexation05/05/2024 4:47:52 PM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack