Scientific article
English

A method for fast automated assessment of the magnetic resonance parkinsonism index

Published in

Neuroradiology, vol. 62, no. 6, p. 747-751

Publication date

2020

Abstract

In patients with parkinsonian syndromes, and particularly during the early stages of the clinical disease, differentiating between idiopathic Parkinson's disease and progressive supranuclear palsy is challenging. Imaging plays an important role in early diagnosis, and the magnetic resonance parkinsonism index was shown to reliably differentiate between the two entities. Calculation of the index is a time-consuming process. We developed an algorithm allowing its automatic calculation based on 3D T1-weighted images, producing additional color-coded images for verification.

Keywords

  • Parkinson index
  • MRI
  • 3DT1
  • Parkinson
  • MRI
  • Automated assessment
  • Automated calculation
  • MRPI
  • PSP
  • Parkinson's disease

Citation (ISO format)

SCHEFFLER, Max et al. A method for fast automated assessment of the magnetic resonance parkinsonism index. In: Neuroradiology, 2020, vol. 62, n° 6, p. 747–751. doi: 10.1007/s00234-020-02380-5

Main files (1)

Article (Published version)

Identifiers

Journal ISSN

0028-3940
317views
5downloads

Technical informations

Creation

27/02/2020 13:08:00

First validation

27/02/2020 13:08:00

Update

15/03/2023 21:59:05

Status update

15/03/2023 21:59:05

Last indexation

31/10/2024 18:43:34
All rights reserved by Archive ouverte UNIGE and the University of Geneva
OpenAIRE Indexed & Validated