Characterization of flow reduction properties in an aneurysm due to a stent

Authors
Published in Physical Review. E, Statistical Physics, Plasmas, Fluids and Related Interdisciplinary Topics. 2003, vol. 68, no. 021918, p. 1-6
Abstract We consider a lattice Boltzmann simulation of blood flow in a vessel deformed by the presence of an aneurysm. Modern clinical treatments involve introducing a stent (a tubular mesh of wires) into the cerebral artery in order to reduce the flow inside the aneurysm and favor its spontaneous reabsorption. A crucial question is to design the stent with suitable porosity so as to produce the most effective flow reduction. We propose a stent positioning factor as a characterizing tool for stent pore design in order to describe the flow reduction effect and reveal the several flow reduction mechanisms using this effect.
Identifiers
Full text
Structures
Research group Scientific and Parallel Computing
Citation
(ISO format)
HIRABAYASHI, Miki et al. Characterization of flow reduction properties in an aneurysm due to a stent. In: Physical Review. E, Statistical Physics, Plasmas, Fluids and Related Interdisciplinary Topics, 2003, vol. 68, n° 021918, p. 1-6. doi: 10.1103/PhysRevE.68.021918 https://archive-ouverte.unige.ch/unige:120888