Scientific article
German

Ahmed Glaucoma Valve über Pars-plana-Zugang: Langzeitergebnisse von Implantationen bei therapierefraktärem Glaukom

Published inDer Ophthalmologe, vol. 110, no. 6, p. 537-542
Publication date2013
Abstract

Aim of this study is the presentation of long-term results regarding the effectiveness and safety of the implantation of Ahmed glaucoma valve (AGV) devices using a pars plana approach after vitrectomy in the treatment of therapy refractive glaucoma.

Keywords
  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Child
  • Chronic Disease
  • Female
  • Glaucoma/complications/diagnosis/surgery
  • Glaucoma Drainage Implants
  • Humans
  • Male
  • Middle Aged
  • Ocular Hypertension/etiology/prevention & control
  • Prosthesis Implantation/methods
  • Treatment Outcome
  • Vitrectomy/instrumentation/methods
Affiliation entities Not a UNIGE publication
Citation (ISO format)
MAZINANI, B et al. Ahmed Glaucoma Valve über Pars-plana-Zugang: Langzeitergebnisse von Implantationen bei therapierefraktärem Glaukom. In: Der Ophthalmologe, 2013, vol. 110, n° 6, p. 537–542. doi: 10.1007/s00347-012-2685-x