Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor

Published inPloS one, vol. 10, no. 6, e0129529
Publication date2015
Abstract

Purpose: To compare estimates of 24-hour intraocular pressure (IOP) peak timing and variation obtained using a contact lens sensor (CLS) and using a pneumatonometer.

Methods: Laboratory data collected from 30 healthy volunteers (ages, 20-66 years) in a randomized, controlled clinical trial were analyzed. Participants were housed for 24 hours in a sleep laboratory. One randomly selected right or left eye was fitted with a CLS that monitored circumferential curvature in the corneoscleral region related to the change of IOP. Electronic output signals of 30 seconds were averaged and recorded every 5 minutes. In the contralateral eye, habitual IOP measurements were taken using a pneumatonometer once every two hours. Simulated 24-hour rhythms in both eyes were determined by cosinor fitting. Simulated peak timings (acrophases) and simulated data variations (amplitudes) were compared between the paired eyes.

Results: Bilateral change patterns of average 24-hour data for the group were in parallel. The simulated peak timing in the CLS fitted eye occurred at 4:44 AM ± 210 min (mean ± SD) and the IOP peak timing in the contralateral eye at 4:11 AM ± 120 min (P=0.256, Wilcoxon signed-rank test). There was no significant correlation between the simulated data variations in the paired eyes (P=0.820, linear regression).

Conclusions: The 24-hour CLS data showed a simulated peak timing close to the 24-hour IOP peak timing obtained using the pneumatonometer. However, the simulated variations of 24-hour data in the paired eyes were not correlated. Estimated 24-hour IOP rhythms using the two devices should not be considered interchangeable.

Keywords
  • Adult
  • Aged
  • Contact Lenses
  • Female
  • Humans
  • Intraocular Pressure
  • Male
  • Middle Aged
  • Time Factors
  • Tonometry, Ocular/methods
  • Young Adult
Citation (ISO format)
LIU, John H K, MANSOURI, Kaweh, WEINREB, Robert N. Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor. In: PloS one, 2015, vol. 10, n° 6, p. e0129529. doi: 10.1371/journal.pone.0129529
Main files (1)
Article (Published version)
Identifiers
Journal ISSN1932-6203
519views
313downloads

Technical informations

Creation29/11/2016 14:45:00
First validation29/11/2016 14:45:00
Update11/10/2023 09:27:21
Status update11/10/2023 09:27:21
Last indexation31/10/2024 05:39:39
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack