Scientific article
OA Policy
English

The influence of antagonist standardization on wear

Published inJournal of dental research, vol. 78, no. 2, p. 713-719
Publication date1999
Abstract

For differences among materials to be easily detected, low variation in in vitro wear tests is desirable. The working hypothesis of this paper was that antagonists standardized for shape and size and according to materials would show mean values similar to those found in natural, non-standardized cusps, and that standardization would lead to a reduction in mean variation. First, the shapes and sizes of palatal cusps of non-erupted human upper third molars were measured. The cusp cupola was best described by the formula y = 0.001 x2 and was symmetrical around the axis of rotation. Up to 200 microm of the y-axis, this parabola corresponded best to a ball radius of 0.6 mm. Based on this information, standardized antagonists were fabricated from both human enamel and steatite. Wear in the occlusal contact area and the wear of opposing conventional ceramic and fine hybrid composite, respectively, were quantified in a computerized chewing simulator. As a control, natural human enamel cusps were used. Standardization of enamel cusps did not reduce the variation of the resulting wear compared with that of non-standardized enamel antagonists. Furthermore, standardization led to significantly different results both in the antagonists and in the opposing restorative materials. Thus, natural enamel antagonists are preferable for the simulation of wear in the occlusal contact area.

Keywords
  • Analysis of Variance
  • Bite Force
  • Composite Resins/chemistry
  • Dental Enamel/chemistry
  • Dental Porcelain/chemistry
  • Dental Restoration Wear
  • Hardness Tests/standards
  • Humans
  • Magnesium Oxide/chemistry
  • Mastication
  • Materials Testing/standards
  • Reference Standards
  • Silicon Dioxide/chemistry
  • Tooth Crown/anatomy & histology/physiology
  • Antagonist standardization
  • Wear
  • In vitro test
  • Steatite
  • Enanel
Citation (ISO format)
KREJCI, Ivo, ALBERT, P., LUTZ, F. The influence of antagonist standardization on wear. In: Journal of dental research, 1999, vol. 78, n° 2, p. 713–719. doi: 10.1177/00220345990780021201
Main files (1)
Article (Published version)
accessLevelPublic
Identifiers
Journal ISSN0022-0345
528views
380downloads

Technical informations

Creation01/03/2016 07:30:00
First validation01/03/2016 07:30:00
Update20/02/2026 12:52:57
Status update20/02/2026 12:52:57
Last indexation20/02/2026 12:56:19
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack