Ballistocardiogram artifact correction taking into account physiological signal preservation in simultaneous EEG-fMRI

Published inNeuroImage, vol. 135, p. 45-63
Publication date2016
Abstract

The ballistocardiogram (BCG) artifact is currently one of the most challenging in the EEG acquired concurrently with fMRI, with correction invariably yielding residual artifacts and/or deterioration of the physiological signals of interest. In this paper, we propose a family of methods whereby the EEG is decomposed using Independent Component Analysis (ICA) and a novel approach for the selection of BCG-related independent components (ICs) is used (PROJection onto Independent Components, PROJIC). Three ICA-based strategies for BCG artifact correction are then explored: 1) BCG-related ICs are removed from the back-reconstruction of the EEG (PROJIC); and 2-3) BCG-related ICs are corrected for the artifact occurrences using an Optimal Basis Set (OBS) or Average Artifact Subtraction (AAS) framework, before back-projecting all ICs onto EEG space (PROJIC-OBS and PROJIC-AAS, respectively). A novel evaluation pipeline is also proposed to assess the methods performance, which takes into account not only artifact but also physiological signal removal, allowing for a flexible weighting of the importance given to physiological signal preservation. This evaluation is used for the group-level parameter optimization of each algorithm on simultaneous EEG-fMRI data acquired using two different setups at 3T and 7T. Comparison with state-of-the-art BCG correction methods showed that PROJIC-OBS and PROJIC-AAS outperformed the others when priority was given to artifact removal or physiological signal preservation, respectively, while both PROJIC-AAS and AAS were in general the best choices for intermediate trade-offs. The impact of the BCG correction on the quality of event-related potentials (ERPs) of interest was assessed in terms of the relative reduction of the standard error (SE) across trials: 26/66%, 32/62% and 18/61% were achieved by, respectively, PROJIC, PROJIC-OBS and PROJIC-AAS, for data collected at 3T/7T. Although more significant improvements were achieved at 7T, the results were qualitatively comparable for both setups, which indicate the wide applicability of the proposed methodologies and recommendations.

Research group
Citation (ISO format)
ABREU, Rodolfo et al. Ballistocardiogram artifact correction taking into account physiological signal preservation in simultaneous EEG-fMRI. In: NeuroImage, 2016, vol. 135, p. 45–63. doi: 10.1016/j.neuroimage.2016.03.034
Main files (1)
Article (Accepted version)
accessLevelRestricted
Identifiers
ISSN of the journal1053-8119
482views
0downloads

Technical informations

Creation04/29/2016 5:27:00 PM
First validation04/29/2016 5:27:00 PM
Update time03/15/2023 12:22:34 AM
Status update03/15/2023 12:22:33 AM
Last indexation01/16/2024 8:51:48 PM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack