Scientific article
English

SPECT-CT Assessment of Pseudarthrosis after Spinal Fusion: Diagnostic Pitfall due to a Broken Screw

Published in

Case reports in orthopedics, vol. 2013, 502517

Publication date

2013

Abstract

A 43-year-old drug addicted female was referred for a L5-S1 posterolateral in situ fixation with autologous graft because of an L5/S1 severe discopathy with listhesis. After six months, low back pain recurred. A Tc-99m HDP SPECT-CT diagnosed a pseudarthrosis with intense uptake of the L5-S1 endplates and a fracture of the right S1 screw just outside the metal-bone interface without any uptake or bone resorption around the screw. The absence of uptake around a broken screw is a pitfall that the physician should be aware of.

Citation (ISO format)

RAGER, Olivier et al. SPECT-CT Assessment of Pseudarthrosis after Spinal Fusion: Diagnostic Pitfall due to a Broken Screw. In: Case reports in orthopedics, 2013, vol. 2013, p. 502517. doi: 10.1155/2013/502517

Main files (1)

Article (Published version)

Identifiers

Journal ISSN

2090-6757
581views
0downloads

Technical informations

Creation

27/11/2015 11:42:00

First validation

27/11/2015 11:42:00

Update

14/03/2023 23:57:05

Status update

14/03/2023 23:57:05

Last indexation

31/10/2024 02:14:10
All rights reserved by Archive ouverte UNIGE and the University of Geneva
OpenAIRE Indexed & Validated