Scientific article
English

Quantification of tremor and bradykinesia in Parkinson's disease using a novel ambulatory monitoring system

Published inIEEE transactions on biomedical engineering, vol. 54, no. 2, p. 313-322
Publication date2007
Abstract

An ambulatory system for quantification of tremor and bradykinesia in patients with Parkinson's disease (PD) is presented. To record movements of the upper extremities, a sensing units which included miniature gyroscopes, has been fixed to each of the forearms. An algorithm to detect and quantify tremor and another algorithm to quantify bradykinesia have been proposed and validated. Two clinical studies have been performed. In the first study, 10 PD patients and 10 control subjects participated in a 45-min protocol of 17 typical daily activities. The algorithm for tremor detection showed an overall sensitivity of 99.5% and a specificity of 94.2% in comparison to a video reference. The estimated tremor amplitude showed a high correlation to the Unified Parkinson's Disease Rating Scale (UPDRS) tremor subscore (e.g., r = 0.87, p < 0.001 for the roll axis). There was a high and significant correlation between the estimated bradykinesia related parameters estimated for the whole period of measurement and respective UPDRS subscore (e.g., r = -0.83, p < 0.001 for the roll axis). In the second study, movements of upper extremities of 11 PD patients were recorded for periods of 3-5 hr. The patients were moving freely during the measurements. The effects of selection of window size used to calculate tremor and bradykinesia related parameters on the correlation between UPDRS and these parameters were studied. By selecting a window similar to the period of the first study, similar correlations were obtained. Moreover, one of the bradykinesia related parameters showed significant correlation (r = -0.74, p < 0.01) to UPDRS with window sizes as short as 5 min. Our study provides evidence that objective, accurate and simultaneous assessment of tremor and bradykinesia can be achieved in free moving PD patients during their daily activities.

Keywords
  • Aged
  • Diagnosis, Computer-Assisted/instrumentation/methods
  • Equipment Design
  • Equipment Failure Analysis
  • Female
  • Humans
  • Hypokinesia/diagnosis/etiology/physiopathology
  • Male
  • Middle Aged
  • Monitoring, Ambulatory/instrumentation/methods
  • Parkinson Disease/complications/diagnosis/physiopathology
  • Pattern Recognition, Automated/methods
  • Reproducibility of Results
  • Sensitivity and Specificity
Citation (ISO format)
SALARIAN, Arash et al. Quantification of tremor and bradykinesia in Parkinson’s disease using a novel ambulatory monitoring system. In: IEEE transactions on biomedical engineering, 2007, vol. 54, n° 2, p. 313–322. doi: 10.1109/TBME.2006.886670
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN0018-9294
601views
0downloads

Technical informations

Creation15/01/2015 17:49:00
First validation15/01/2015 17:49:00
Update time14/03/2023 22:43:04
Status update14/03/2023 22:43:03
Last indexation30/10/2024 22:21:01
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack