An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy

Publié dansPhysics in medicine and biology, vol. 56, no. 12, p. 3563-3582
Date de publication2011
Résumé

A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm(-2) CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.

Mots-clés
  • Abdomen/surgery
  • Acoustics
  • Equipment Design
  • High-Intensity Focused Ultrasound Ablation/instrumentation
  • Magnetic Resonance Imaging/instrumentation
  • Models, Theoretical
  • Transducers
Citation (format ISO)
AUBOIROUX, Vincent et al. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy. In: Physics in medicine and biology, 2011, vol. 56, n° 12, p. 3563–3582. doi: 10.1088/0031-9155/56/12/008
Fichiers principaux (1)
Article (Published version)
accessLevelRestricted
Identifiants
ISSN du journal0031-9155
561vues
0téléchargements

Informations techniques

Création24/11/2014 4:58:00 ΜΜ
Première validation24/11/2014 4:58:00 ΜΜ
Heure de mise à jour14/03/2023 10:29:37 ΜΜ
Changement de statut14/03/2023 10:29:37 ΜΜ
Dernière indexation18/10/2023 9:05:07 ΜΜ
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack