Diagnosis of urothelial tumors with a dedicated dual-source dual-energy MDCT protocol: preliminary results

Authors
Published in American Journal of Roentgenology. 2014, vol. 202, no. 4, p. W357-64
Abstract The purpose of this study was to evaluate the diagnostic performance of a dedicated dual-source dual-energy MDCT (DECT) protocol for the detection of urothelial tumors.
Keywords AdultAgedAged, 80 and overContrast Media/diagnostic useDiagnosis, DifferentialFemaleHumansIohexol/diagnostic useMaleMiddle AgedMultidetector Computed Tomography/methodsRadiographic Image Interpretation, Computer-AssistedRadiography, Dual-Energy Scanned Projection/methodsRetrospective StudiesUrinary Bladder Neoplasms/pathology/radiographyUrothelium/pathology/radiography
Identifiers
PMID: 24660734
Full text
Article (Published version) (1 MB) - document accessible for UNIGE members only Limited access to UNIGE
Structures
Research groups Imagerie et radiologie interventionnelle du foie, des voies biliaires et du pancréas (316)
Imagerie per-opératoire multi-modalité en radiologie interventionnelle (949)
Citation
(ISO format)
HANSEN, Catrina et al. Diagnosis of urothelial tumors with a dedicated dual-source dual-energy MDCT protocol: preliminary results. In: American Journal of Roentgenology, 2014, vol. 202, n° 4, p. W357-64. https://archive-ouverte.unige.ch/unige:43041