en
Scientific article
English

Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis

Published inJournal of vascular surgery, vol. 59, no. 1, p. 210-219
Publication date2014
Abstract

There is a continuous search for shelf-ready small-caliber vascular prostheses with satisfactory early and late results. Biodegradable scaffolds, repopulated by recipient's cells regenerating a neovessel, can be a suitable option for adult and pediatric, urgent and elective cardiovascular procedures. METHODS: This was a short-term experimental assessment of a new biodegradable vascular prosthesis for arterial replacement in the pig. Eleven pigs underwent bilateral carotid artery replacement with biodegradable electrospun poly-ε-caprolactone (PCL) nanofiber prostheses (internal diameter, 4 mm; length, 5 cm); or expanded polytetrafluoroethylene (ePTFE) prostheses as control. Perioperative anticoagulation was achieved with intravenous heparin (double baseline activated clotting time). Postoperatively, until conclusion of the study at 1 month, animals received aspirin and clopidogrel daily. Transit time flow was measured intraoperatively and at sacrifice. Doppler ultrasound (1 and 4 weeks) and a selective carotid angiography (4 weeks) were performed to assess patency. All explanted grafts were analyzed by histology, morphometry, and scanning electron microscopy in order to study graft-host interaction. RESULTS: Surgical handling and hemostasis of the new prostheses were excellent. Patency rate was 78% (7/9) for PCL grafts, compared with 67% (4/6) for ePTFE grafts. Transit time flow and Doppler ultrasound showed no significant changes in flow and velocity or diameter over time in both groups. Both prostheses showed no detectable in vivo compliance as compared with native carotid artery. Percent neoendothelialization was 86% for PCL and 58% for ePTFE grafts (P = .008). Neointima formation was equal in both grafts. More adventitial infiltration of macrophages, myofibroblasts, and capillaries was seen in PCL grafts with a milder foreign-body reaction when compared with ePTFE implants. Both grafts showed similar endoluminal thrombus formation. CONCLUSIONS: Biodegradable, electrospun PCL grafts showed good surgical and mechanical properties, no aneurysm formation, and similar short-term patency compared with ePTFE grafts. Rapid endothelialization and cell ingrowth confirms favorable PCL graft-recipient biological interaction. Despite good early results, long-term follow-up is required before clinical application.

Citation (ISO format)
MROWCZYNSKI, Wojciech et al. Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis. In: Journal of vascular surgery, 2014, vol. 59, n° 1, p. 210–219. doi: 10.1016/j.jvs.2013.03.004
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
ISSN of the journal0741-5214
557views
0downloads

Technical informations

Creation05/29/2013 9:18:00 AM
First validation05/29/2013 9:18:00 AM
Update time03/14/2023 8:18:41 PM
Status update03/14/2023 8:18:41 PM
Last indexation01/16/2024 1:49:28 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack