UNIGE document Scientific Article
previous document  unige:26521  next document
add to browser collection
Title

Respiratory change in ECG-wave amplitude is a reliable parameter to estimate intravascular volume status

Authors
Published in Journal of Clinical Monitoring and Computing. 2012
Abstract Electrocardiogram (ECG) is a standard type of monitoring in intensive care medicine. Several studies suggest that changes in ECG morphology may reflect changes in volume status. The "Brody effect", a theoretical analysis of left ventricular (LV) chamber size influence on QRS-wave amplitude, is the key element of this phenomenon. It is characterised by an increase in QRS-wave amplitude that is induced by an increase in ventricular preload. This study investigated the influence of changes in intravascular volume status on respiratory variations of QRS-wave amplitudes (ΔECG) compared with respiratory pulse pressure variations (ΔPP), considered as a reference standard. In 17 pigs, ECG and arterial pressure were recorded. QRS-wave amplitude was measured from the Biopac recording to ensure that in all animals ECG electrodes were always at the same location. Maximal QRS amplitude (ECGmax) and minimal QRS amplitude (ECGmin) were determined over one respiratory cycle. ΔECG was calculated as 100 × [(ECGmax - ECGmin)/(ECGmax + ECGmin)/2]. ΔECG and ΔPP were simultaneously recorded. Measurements were performed at different time points: during normovolemic conditions, after haemorrhage (25 mL/kg), and following re-transfusion (25 mL/kg) with constant tidal volume (10 mL/kg) and respiration rate (15 breath/min). At baseline, ΔPP and ΔECG were both <12 %. ΔPP were significantly correlated with ΔECG (r(2) = 0.89, p < 0.001). Volume loss induced by haemorrhage increased significantly ΔPP and ΔECG. Moreover, during this state, ΔPP were significantly correlated with ΔECG (r(2) = 0.86, p < 0.001). Re-transfusion significantly decreased ΔPP and ΔECG, and ΔPP were significantly correlated with ΔECG (r(2) = 0.90, p < 0.001). The observed correlations between ΔPP and ΔECG at each time point of the study suggest that ΔECG is a reliable parameter to estimate the changes in intravascular volume status and provide experimental confirmation of the "Brody effect."
Identifiers
PMID: 23117586
Full text
Article (Published version) (365 Kb) - document accessible for UNIGE members only Limited access to UNIGE
Structures
Research groups Groupe de Recherche en Hémodynamique (913)
Réanimation respiratoire (924)
Citation
(ISO format)
GIRAUD, Raphaël et al. Respiratory change in ECG-wave amplitude is a reliable parameter to estimate intravascular volume status. In: Journal of Clinical Monitoring and Computing, 2012. https://archive-ouverte.unige.ch/unige:26521

207 hits

0 download

Update

Deposited on : 2013-03-01

Export document
Format :
Citation style :