UNIGE document Scientific Article
previous document  unige:24418  next document
add to browser collection
Title

High time-resolved cardiac functional imaging using temporal regularization for small animal on a clinical 3T scanner

Authors
Published in IEEE Transactions on Biomedical Engineering. 2012, vol. 59, no. 4, p. 929-35
Abstract Accurate assessment of mice cardiac function with magnetic resonance imaging is essential for longitudinal studies and for drug development related to cardiovascular diseases. Whereas dedicated small animal MR scanners are not readily available, it would be a great advantage to be able to perform cardiac assessment on clinical systems, in particular, in the context of translational research. However, mouse imaging remains challenging since it requires both high spatial and temporal resolutions, while gradient performances of clinical scanners often limit the reachable parameters. In this study, we propose a new cine sequence, named "interleaved cine," which combines two repetitions of a standard cine sequence shifted in time in order to reach resolution parameters compatible with mice imaging. More precisely, this sequence allows temporal resolution to be reduced to 6.8 ms instead of 13.5 ms initially imposed by the system's hardware. We also propose a two-step denoising algorithm to suppress some artifacts inherent to the new interleaved cine thus allowing an efficient enhancement of the image quality. In particular, we model and suppress the periodic intensity pattern and further denoise the sequence by soft thresholding of the temporal Fourier coefficients. This sequence was successfully validated with mass and function measurements on relevant mice models of cardiovascular diseases.
Keywords AlgorithmsAnimalsHypertrophy, Left Ventricular/pathology/physiopathologyImage Enhancement/instrumentation/methodsMagnetic Resonance Imaging, Cine/instrumentation/methods/veterinaryMaleMiceMice, Inbred C57BLReproducibility of ResultsSensitivity and Specificity
Identifiers
PMID: 22057042
Full text
Article (Published version) (819 Kb) - document accessible for UNIGE members only Limited access to UNIGE
Structures
Research groups Imagerie cardiaque fonctionnelle (541)
L'athérosclérose et ses complications cliniques (591)
Traitement d'images médicales (893)
Biologie du myocarde (22)
Citation
(ISO format)
DELATTRE, Bénédicte et al. High time-resolved cardiac functional imaging using temporal regularization for small animal on a clinical 3T scanner. In: IEEE Transactions on Biomedical Engineering, 2012, vol. 59, n° 4, p. 929-35. https://archive-ouverte.unige.ch/unige:24418

166 hits

2 downloads

Update

Deposited on : 2012-12-11

Export document
Format :
Citation style :