en
Scientific article
Open access
English

Comparative evaluation of active contour model extensions for automated cardiac MR image segmentation by regional error assessment

Published inMagma, vol. 20, no. 2, p. 69-82
Collection
  • Open Access - Licence nationale Springer
Publication date2007
Abstract

OBJECTIVE: In the field of cardiac MR image segmentation, active contour models, or snakes have been extensively used, owing to their promising results and to the numerous extensions proposed to improve their performance. This paper explores a methodology for evaluating cardiac MR image segmentation algorithms, which assesses the distance between computer-generated and the observer's hand-outlined boundaries. This metric was applied to various external force extensions of the traditional snake, since no systematic comparison has been performed. MATERIALS AND METHODS: Cardiac MRI from six patients were analyzed. Imaging was performed on a 1.5 T MR scanner with ECG-gated balanced steady-state free precession (b-SSFP) sequences. Segmentation performances were established for traditional snake, gradient vector flow snake, standard- and guided- pressure force-based snake. The use of a pre-treatment with non-linear anisotropic filtering was also compared to non-filtered images. RESULTS: Agreement between manual and segmentation algorithms was satisfactory for ejection fraction for every segmentation scheme. However end-systolic and end-diastolic volumes were systematically underestimated. CONCLUSION: The developed regional error metric provided a more rigorous evaluation of the segmentation schemes in comparison to the classical derived parameters based on left ventricle volume estimation, usually used in functional cardiac MR studies. These derived parameters can furthermore mask local segmentation errors.

Keywords
  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms
  • Artificial Intelligence
  • Cardiomyopathies/diagnosis
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted/methods
  • Magnetic Resonance Imaging/methods
  • Male
  • Middle Aged
  • Myocardium/pathology
  • Pattern Recognition, Automated/methods
  • Reproducibility of Results
  • Sensitivity and Specificity
Citation (ISO format)
NGUYEN, Duy, MASTERSON, Karen, VALLÉE, Jean-Paul. Comparative evaluation of active contour model extensions for automated cardiac MR image segmentation by regional error assessment. In: Magma, 2007, vol. 20, n° 2, p. 69–82. doi: 10.1007/s10334-007-0069-z
Main files (1)
Article (Published version)
accessLevelPublic
Identifiers
ISSN of the journal0968-5243
567views
230downloads

Technical informations

Creation07/02/2009 8:18:00 AM
First validation07/02/2009 8:18:00 AM
Update time03/14/2023 3:09:31 PM
Status update03/14/2023 3:09:31 PM
Last indexation05/02/2024 11:12:14 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack