UNIGE document Scientific Article - Review
previous document  unige:20898  next document
add to browser collection
Title

Comparison of cardiac output as assessed by transesophageal echo-Doppler and transpulmonary thermodilution in patients undergoing thoracic surgery

Authors
Diaper, John
Inan, Cidgem
Published in Journal of Clinical Anesthesia. 2010, vol. 22, no. 2, p. 97-103
Abstract STUDY OBJECTIVE: To evaluate the accuracy of cardiac index (CI) as measured by echo-transesophageal Doppler monitoring (echo-TDM) with CI measured by the transpulmonary thermodilution technique. DESIGN: Prospective, observational study. SETTING: University hospital. PATIENTS: 16 patients scheduled for elective lung cancer resection. INTERVENTIONS: Patients underwent two-lung ventilation (TLV) and one-lung ventilation (OLV). MEASUREMENTS AND MAIN RESULTS: CI measurements were analyzed using Bland-Altman plots. Absolute values of CI as measured by both devices were highly correlated (r(2) ranging from 0.72 to 0.77), as were relative changes in CI after the start of OLV (r(2) = 0.48, P = 0.006). Before, during, and after OLV, TDM-CI biases were 0.46 +/- 0.28 L/min/m(2), 0.25 +/- 0.18 L/min/m(2), and 0.35 +/- 0.29 L/min/m(2), respectively. Limits of agreement remained stable throughout the three measurement periods (range -1.08 to 0.21 L/min/m(2)). The mean percentage error of CI measurements was 21.9% compared with the thermodilution technique. Although no adverse events were reported, 11% of measurement sets were incomplete due to poor signal detection. CONCLUSIONS: Echo-TDM is a safe technique, allowing continuous semi-invasive assessment of hemodynamic changes in most patients undergoing open-chest surgery. Doppler-derived CI values showed significant biases and moderate clinical agreement with transpulmonary thermodilution during TLV and OLV.
Keywords AgedBlood Pressure/physiologyCardiac Output/ physiologyEchocardiography, Doppler, PulsedEchocardiography, TransesophagealHeart Rate/physiologyHumansLung Neoplasms/surgeryMiddle AgedPneumonectomyProspective StudiesRespiration, Artificial/methodsThermodilutionTreatment Outcome
Identifiers
PMID: 20304350
Full text
Article - document accessible for UNIGE members only Limited access to UNIGE
Other version: http://www.sciencedirect.com/science/journal/09528180
Structures
Research groups Dysfonctions cardio-pulmonaires et cérébrales (278)
Chirurgie thoracique et chirurgie endocrinologique (573)
Citation
(ISO format)
DIAPER, John et al. Comparison of cardiac output as assessed by transesophageal echo-Doppler and transpulmonary thermodilution in patients undergoing thoracic surgery. In: Journal of Clinical Anesthesia, 2010, vol. 22, n° 2, p. 97-103. https://archive-ouverte.unige.ch/unige:20898

205 hits

0 download

Update

Deposited on : 2012-05-23

Export document
Format :
Citation style :