Scientific article
OA Policy
English

Segmented Intraoral Scanning With a Palatal Marker for Complete‐Arch Digital Implant Impressions : An In Vitro Comparative Study

Published in

Clinical oral implants research, vol. 37, no. 10, p. 1208-1216

Publication date

2026-10

First online date

2026-07-27

Abstract

Objectives: To compare four complete-arch implant impression workflows-segmented right/left IOS merged via a palatal marker (IOS-LEGO-Seg), continuous full-arch IOS with a palatal marker (IOS-LEGO-Full), continuous full-arch IOS without a palatal marker (IOS-Full), and a conventional open-tray PVS impression followed by cast fabrication and cast scanning (CI)-and to evaluate whether segmentation combined with a palatal marker improves agreement with a laboratory reference dataset in a maxillary edentulous model.

Material and methods: A maxillary edentulous dental cast with six implants was used to compare IOS-LEGO-Seg, IOS-LEGO-Full, IOS-Full, and CI. Intraoral scans were acquired, with 10 repetitions per condition. Datasets were superimposed onto a master reference scan using three alveolar-ridge markers; the palatal marker was excluded. The primary outcome was the concordance rate, defined as the proportion of intraoral scan body surface points within ±50 μm of the reference. A linear mixed-effects model was used to compare workflows (α = 0.05).

Results: IOS-LEGO-Seg achieved the highest concordance, followed by IOS-LEGO-Full, IOS-Full, and CI (p < 0.001). The concordance rate was comparable between the IOS-LEGO-Full and IOS-Full groups, indicating that the addition of a palatal marker alone did not improve accuracy. Site-specific analysis revealed lower concordance at the distal molars (#16 and #26) in the non-segmented IOS workflows; however, this effect was mitigated by the segmented approach. The CI group did not show site-specific differences.

Conclusions: The segmented workflow with a palatal marker may represent an accessible strategy for improving the accuracy of maxillary complete-arch implant impressions.

Keywords

  • Dental implants
  • Dental impression technique
  • Three‐dimensional imaging

UNIGE research groups

Citation (ISO format)

IKUMI, Reo et al. Segmented Intraoral Scanning With a Palatal Marker for Complete‐Arch Digital Implant Impressions : An In Vitro Comparative Study. In: Clinical oral implants research, 2026, vol. 37, n° 10, p. 1208–1216. doi: 10.1111/clr.70161

Main files (1)

Article (Published version)

Identifiers

Journal ISSN

0905-7161
5views
8downloads

Technical informations

Creation

17/10/2026 15:55:03

First validation

16/11/2026 09:28:48

Update

16/11/2026 09:28:48

Status update

16/11/2026 09:28:48

Last indexation

16/11/2026 09:28:50
All rights reserved by Archive ouverte UNIGE and the University of Geneva
OpenAIRE Indexed & Validated