Scientific article
OA Policy
English

Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation

Published inZeitschrift für medizinische Physik, vol. 35, no. 1, p. 87-97
Publication date2025-02
First online date2024-07-02
Abstract

Purpose: To apply velocity selective arterial spin labeling (VSASL) combined with a navigator-based (NAV) prospective motion compensation method for a free-breathing liver perfusion measurement without contrast agent.

Methods: Sinc-modulated Velocity Selective Inversion (sinc-VSI) pulses were applied as labeling and control pulses. In order to account for respiratory motion, a navigator was employed in the form of a single gradient-echo projection readout, located at the diaphragm along the inferior-superior direction. Prior to each transverse imaging slice of the spin-echo EPI based readouts, navigator and fat suppression were incorporated. Motion data was obtained from the navigator and transmitted back to the sequence, allowing real-time adjustments to slice positioning. The sinc-VSI without velocity-selective gradients during the control condition but with velocity-selective gradients along all three directions during labeling was chosen for the VSASL. The VSASL was compared with pseudo-continuous ASL (pCASL) methods, which selectively tagged the moving spins using a tagging plane placed at the portal vein and hepatic artery.

Results: The motion caused by respiratory activity was effectively computed using the navigator signal. The coefficients of variation (CoV) of average liver voxel in NAV were significantly decreased when compared to breath-hold (BH), with an average reduction of 29.4 ± 18.44% for control images, and 29.89 ± 20.83% for label images (p < 0.001). The resulting maps of normalized ASL signal (normalized to M0 ) showed significantly higher perfusion weightings in the NAV-compensated VSASL, when compared to the NAV-compensated pCASL techniques.

Conclusions: This study demonstrates the feasibility of using a navigator-based prospective motion compensation technique in conjunction with VSASL for the measurement of liver perfusion without the use of contrast agents while allowing for free-breathing.

Keywords
  • Liver perfusion
  • Navigator-based slice tracking
  • Prospective motion compensation
  • Velocity selective arterial spin labeling
  • Humans
  • Liver / diagnostic imaging
  • Liver / blood supply
  • Respiration
  • Perfusion Imaging / methods
  • Motion
  • Male
  • Adult
  • Spin Labels
  • Female
Funding
  • Bundesministerium für Bildung und Forschung [82DZL004A1]
  • Deutsche Forschungsgemeinschaft [507778062]
Citation (ISO format)
ZHANG, Ke et al. Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation. In: Zeitschrift für medizinische Physik, 2025, vol. 35, n° 1, p. 87–97. doi: 10.1016/j.zemedi.2024.06.001
Main files (1)
Article (Published version)
Secondary files (2)
Supplemental data
accessLevelPublic
Supplemental data
accessLevelPublic
Identifiers
Journal ISSN0939-3889
2views
4downloads

Technical informations

Creation26/05/2026 13:58:55
First validation22/06/2026 07:29:38
Update22/06/2026 07:29:38
Status update22/06/2026 07:29:38
Last indexation22/06/2026 07:29:39
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack