Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging

Published inMagnetic resonance imaging, vol. 98, p. 26-35
Publication date2023-05
First online date2023-01-02
Abstract

Objectives: To apply a navigator-based slice tracking method to prospectively compensate the respiratory motion for kidney vessel architecture imaging (VAI).

Materials and methods: A dual gradient echo spin echo 2D EPI sequence was developed for kidney VAI. A single gradient-echo slice selection and projection readout at the location of the diaphragm along the inferior-superior direction was applied as a navigator. Navigator acquisition and fat suppression were inserted before each transverse imaging slice. Motion information was calculated after exclusion of the signal saturation in the navigator signal caused by imaging slices. The motion information was then directly sent back to the sequence and slice positioning was adjusted in real-time. The whole sequence was applied during a contrast agent pass-through.

Results: VAI parametric maps show the structural heterogeneity of the renal vasculature. The respiratory motion from the navigator signal was precisely calculated and slice positioning was changed in real-time based on the motion information. The vibration amplitude of the signal intensity of the liver tissue at the liver-lung interface in the case of prospective motion correction (PMC) on is about 28% of the PMC off case. Compared to the case of PMC off, the coefficient of variation was reduced 30% of the case of PMC on.

Conclusions: This study demonstrates the feasibility of the motion-compensating technique in kidney VAI. The sequence may improve the evaluation of microvasculature in kidney diseases.

Keywords
  • Kidney, prospective motion correction
  • Vessel architecture imaging
  • Prospective Studies
  • Contrast Media / chemistry
  • Liver
  • Magnetic Resonance Imaging / methods
  • Motion
  • Artifacts
Affiliation entities Not a UNIGE publication
Citation (ISO format)
ZHANG, Ke et al. Navigator-based slice tracking for prospective motion correction in kidney vessel architecture imaging. In: Magnetic resonance imaging, 2023, vol. 98, p. 26–35. doi: 10.1016/j.mri.2023.01.001
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN0730-725X
2views
0downloads

Technical informations

Creation26/05/2026 14:00:27
First validation19/06/2026 09:46:39
Update19/06/2026 09:46:39
Status update19/06/2026 09:46:39
Last indexation19/06/2026 09:46:40
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack