Abstract

Background: Arterial hypotension commonly occurs after anesthesia induction and is associated with negative clinical outcomes. Point-of-care ultrasound examination has emerged as a modality to predict postinduction hypotension (PIH). We performed a systematic review and network meta-analysis of the predictive performance of point-of-care ultrasound tests for PIH in noncardiac, nonobstetrical routine adult surgery.

Methods: Online databases were searched for diagnostic test accuracy studies of point-of-care ultrasound for predicting PIH up to March 30, 2023. The systematic review followed the Cochrane methodology. A Bayesian diagnostic test accuracy network meta-analysis model was used, with PIH as defined by study authors as the main outcome. Risk of bias and applicability were examined through the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) score. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework was used to assess evidence certainty.

Results: A total of 32 studies with 2631 participants were eligible for systematic review. Twenty-six studies with 2258 participants representing 8 ultrasound tests were included in the meta-analysis. Inferior vena cava collapsibility index (22 studies) sensitivity was 60% (95% credible interval [CrI], 49%-72%) and specificity was 83% (CrI, 74%-89%). Carotid artery corrected flow time (2 studies) sensitivity was 91% (CrI, 76%-98%) and specificity was 90% (CrI, 59%-98%). There were serious bias and applicability concerns due to selection bias and inappropriate blinding. The certainty of evidence was very low for all tests.

Conclusions: The predictive performance of point-of-care ultrasound for PIH is uncertain. There is a need for high-quality randomized controlled trials with appropriate blinding and void of selection bias.

Keywords
  • Humans
  • Hypotension / chemically induced
  • Hypotension / diagnostic imaging
  • Hypotension / etiology
  • Hypotension / physiopathology
  • Point-of-Care Systems
  • Predictive Value of Tests
  • Reproducibility of Results
  • Ultrasonography / methods
Citation (ISO format)
SCHORER, Raoul et al. Diagnostic Accuracy of Vascular Ultrasonography for Postanesthesia Induction Hypotension : A Systematic Review and Network Meta-Analysis. In: Anesthesia and analgesia, 2025, vol. 141, n° 1, p. 26–37. doi: 10.1213/ane.0000000000007108
Main files (1)
Article (Published version)
accessLevelRestricted
Secondary files (1)
Supplemental data
accessLevelRestricted
Identifiers
Journal ISSN0003-2999
2views
0downloads

Technical informations

Creation02/18/2026 1:33:46 AM
First validation03/10/2026 8:10:33 AM
Update time03/10/2026 8:10:33 AM
Status update03/10/2026 8:10:33 AM
Last indexation03/10/2026 8:10:34 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack