Abstract

Transapical transcatheter aortic valve implantation (TA-TAVI) is the recognized first choice surgical TAVI access. Expansion of this well-established treatment modality with subsequent broader patient inclusion has accelerated development of second-generation TA-TAVI devices. The Swiss ACURATE TA Symetis valve allows for excellent anatomical positioning, resulting in a very low incidence of paravalvular leaks. The self-expanding stent features an hourglass shape to wedge the native aortic valve annulus. A specially designed delivery system facilitates controlled release aided by tactile operator feedback. The ACURATE TA valve made of three native porcine non-coronary leaflets has received CE approval in September 2011. Since then, this valve is the third most frequently implanted TAVI device with over 1200 implants in Europe and South America. Results from the Symetis ACURATE TA™ Valve Implantation ('SAVI') Registry showed a procedural success rate of 98.0% and a survival rate of 93.2% at 30 days. This presentation provides technical considerations and detailed procedural aspects of device implantation.

Keywords
  • Nitinol
  • Results
  • Symetis device
  • Technique
  • Transapical aortic valve implantation
  • Aged
  • Aged, 80 and over
  • Alloys / therapeutic use
  • Angiography / methods
  • Aortic Valve / surgery
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery
  • Bioprosthesis
  • Cardiac Catheterization / methods
  • Clinical Trials as Topic
  • Female
  • Heart Valve Prosthesis
  • Humans
  • Intraoperative Care / methods
  • Male
  • Prosthesis Design
  • Prosthesis Fitting / methods
  • Severity of Illness Index
  • Stents
  • Switzerland
  • Transcatheter Aortic Valve Replacement / instrumentation
  • Transcatheter Aortic Valve Replacement / methods
  • Treatment Outcome
Affiliation entities Not a UNIGE publication
Citation (ISO format)
HUBER, Christoph et al. Transapical transcatheter aortic valve implantation using the second-generation self-expanding Symetis ACURATE TA valve. In: Multimedia manual of cardiothoracic surgery, 2014, vol. 2014, p. mmu017. doi: 10.1093/mmcts/mmu017
Main files (1)
Article (Published version) - Screenshot
accessLevelPublic
Identifiers
Additional URL for this publicationhttps://mmcts.org/tutorial/55
Journal ISSN1813-9175
8views
6downloads

Technical informations

Creation26/12/2025 15:21:13
First validation22/01/2026 08:25:39
Update22/01/2026 08:25:39
Status update22/01/2026 08:25:39
Last indexation22/01/2026 08:25:40
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack