Scientific article
Meta-analysis
OA Policy
English

Clinical performance of monolithic CAD/CAM tooth-supported zirconia restorations : systematic review and meta-analysis

Published inJournal of prosthodontic research, vol. 66, no. 3, p. 374-384
Publication date2022-07
First online date2021-10-06
Abstract

Purpose: The purpose of this systematic review was to evaluate the survival rate, biological complications, technical complications, and clinical behavior of single crowns supported by teeth made up in monolithic zirconia with CAD/CAM technology.

Study selection: An extensive electronic search was conducted through Medline/PubMed, Embase, and Cochrane Library databases. Additional manual search was performed on the references of included articles to identify relevant publications. Two reviewers independently performed the selection and electronic and manual search.

Results: From nine articles included, there was a total of 594 participants and 1657 single-tooth restorations with a mean exposure time of 1.07 years, and follow-up period between 0.3 and 2.1 years. All studies showed a moderate level of quality, with a consequent moderate possibility of associated bias, using the Newcastle-Ottawa Scale (NOS), with survival rate (SR) ranging between 91% to 100%. Bleeding on probing (BOP) were reported with an average value of 29.12%. Marginal integrity showed high success rate values for the observation periods, except for one that included patients with bruxism which obtained a SR of 31.60%. Failures and/or fractures, mostly total and requiring replacement, were observed in three studies. Linear regression showed that there was no statistical correlation between survival rate and type of cementation and the average years of follow-up (p=0.730 e p=0.454). There was high heterogeneity between studies (I2 = 93.74% and Q = 79.672).

Conclusion: Within the limitation of this study, monolithic zirconia might be considered as a possible option for restoring single crowns, especially in the posterior zone.

Keywords
  • Computer-aided design
  • Fixed partial denture
  • Tooth crown
  • Yttria-stabilized tetragonal zirconia
  • Zirconium oxide
Affiliation entities Not a UNIGE publication
Citation (ISO format)
LEITÃO, Celina Inês Miranda Brito et al. Clinical performance of monolithic CAD/CAM tooth-supported zirconia restorations : systematic review and meta-analysis. In: Journal of prosthodontic research, 2022, vol. 66, n° 3, p. 374–384. doi: 10.2186/jpr.JPR_D_21_00081
Main files (1)
Article (Published version)
Identifiers
Journal ISSN1883-1958
26views
436downloads

Technical informations

Creation16/07/2025 14:54:59
First validation21/07/2025 09:18:04
Update05/01/2026 14:03:45
Status update05/01/2026 14:03:45
Last indexation05/01/2026 14:03:49
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack