Scientific article
OA Policy
English

An optimized registration workflow and standard geometric space for small animal brain imaging

Published inNeuroImage, vol. 241, 118386
Publication date2021-11
Abstract

The reliability of scientific results critically depends on reproducible and transparent data processing. Cross-subject and cross-study comparability of imaging data in general, and magnetic resonance imaging (MRI) data in particular, is contingent on the quality of registration to a standard reference space. In small animal MRI this is not adequately provided by currently used processing workflows, which utilize high-level scripts optimized for human data, and adapt animal data to fit the scripts, rather than vice-versa. In this fully reproducible article we showcase a generic workflow optimized for the mouse brain, alongside a standard reference space suited to harmonize data between analysis and operation. We introduce four separate metrics for automated quality control (QC), and a visualization method to aid operator inspection. Benchmarking this workflow against common legacy practices reveals that it performs more consistently, better preserves variance across subjects while minimizing variance across sessions, and improves both volume and smoothness conservation RMSE approximately 2-fold. We propose this open source workflow and the QC metrics as a new standard for small animal MRI registration, ensuring workflow robustness, data comparability, and region assignment validity, all of which are indispensable prerequisites for the comparability of scientific results across experiments and centers.

Keywords
  • Animals
  • Brain / diagnostic imaging
  • Brain Mapping / methods
  • Brain Mapping / standards
  • Databases, Factual / standards
  • Female
  • Magnetic Resonance Imaging / methods
  • Magnetic Resonance Imaging / standards
  • Male
  • Mice
  • Mice, Inbred C57BL
  • Neuroimaging / methods
  • Neuroimaging / standards
  • Workflow
Affiliation entities Not a UNIGE publication
Citation (ISO format)
IOANAS, Horea-Ioan et al. An optimized registration workflow and standard geometric space for small animal brain imaging. In: NeuroImage, 2021, vol. 241, p. 118386. doi: 10.1016/j.neuroimage.2021.118386
Main files (1)
Article (Published version)
Identifiers
Journal ISSN1053-8119
26views
20downloads

Technical informations

Creation05/06/2025 10:39:42
First validation06/06/2025 09:05:08
Update18/06/2025 13:52:38
Status update18/06/2025 13:52:38
Last indexation18/06/2025 13:52:39
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack