Scientific article
English

Complexation Behavior and Clinical Assessment of Isomeric Calcium Ionophores of ETH 1001 in Polymeric Ion-Selective Membranes

Published inACS sensors, vol. 9, no. 12, p. 6512-6519
Publication date2024-12-27
First online date2024-11-26
Abstract

Calcium ions are crucial in numerous physiological processes, and their precise measurement is important for many clinical diagnostics and therapeutic interventions. Traditional detection methods, such as atomic absorption spectroscopy, cannot meet clinical requirements, as they measure total calcium instead of the clinically relevant ionized form (Ca2+ ). Ion-selective electrodes (ISEs) provide a convenient, accurate, and specific method for Ca2+ determination. Here, two isomeric calcium ionophores (R ,R )-calcium ionophore I, also known as ETH 1001, and (R ,S )-calcium ionophore I are synthesized and characterized for the analysis of whole blood samples with the Eaglenos blood gas analyzer (model: EG-i30) equipped with test cartridges containing screen-printed electrodes. (R ,R )-Calcium ionophore I demonstrated excellent precision in whole blood samples, achieving an average bias of -2.2% compared with the available gold standard. On the other hand, the (R ,S ) isomer was not satisfactory, exhibiting a bias of up to -20%. Ion transfer voltammetry at thin membrane films gave information about the complex stoichiometry, complex formation constants, and ion selectivity for the two isomeric ionophores. A stoichiometry of the Ca2+ -ionophore complex was confirmed to be 1:2 for both ionophores, while the (R ,R ) isomer gave 3.4 orders of magnitude larger complex formation constants and a modestly higher selectivity. While these data are valuable, the poor performance of membranes containing the (R ,S ) isomer is not directly apparent from the fundamental binding characteristics. It may be caused by interference from lipophilic blood sample components and/or surface adsorption processes, suggesting that routine selectivity characterizations of membranes containing selective ionophores are insufficient to assess their usefulness in clinical applications.

Keywords
  • TEMPO
  • Calcium ionophore
  • Electrochemical sensors
  • Ion transfer voltammetry
  • Ion-selective membrane
Funding
  • China Scholarship Council
Citation (ISO format)
ZHANG, Yupu et al. Complexation Behavior and Clinical Assessment of Isomeric Calcium Ionophores of ETH 1001 in Polymeric Ion-Selective Membranes. In: ACS sensors, 2024, vol. 9, n° 12, p. 6512–6519. doi: 10.1021/acssensors.4c01907
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Additional URL for this publicationhttps://pubs.acs.org/doi/10.1021/acssensors.4c01907
Journal ISSN2379-3694
30views
0downloads

Technical informations

Creation01/04/2025 12:25:22
First validation02/04/2025 11:13:57
Update13/10/2025 11:55:57
Status update02/04/2025 11:13:57
Last indexation22/07/2026 09:12:48
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack