Correlation between referral ultrasound with suspected foetal anomalies and autopsy examination in two prenatal diagnosis centres. Impact of the routine use of 3D/4D scan

Published inPrenatal diagnosis, vol. 28, no. 3, p. 191-196
Publication date2008
Abstract

OBJECTIVE: To compare ultrasound diagnosis with autopsy findings in two tertiary referral foetal medicine centres, only one routinely using 3D and 4D ultrasound, and to compare results between the centres. METHODS: A retrospective study of 138 cases with a termination of pregnancy for foetal abnormalities after 21 weeks' gestation from January 2004 through May 2006 was carried out. We compared prenatal ultrasound and autopsy findings for each organ, calculating the sensitivity, specificity, positive predictive and negative predictive values, and false-positive and false-negative rates for ultrasound. RESULTS: Abnormalities were found most frequently in the brain (48.9%), heart and thorax (34.0%), limbs (31.9%), face (15.9%), and abdomen, urogenital tract and spine (14.5%). Sensitivity between centres did not differ statistically for the brain, spine, limbs and abdomen, but was different for the face (p = 0.005) and heart (p = 0.007). The detection rate was higher for facial malformations at the centre with routine 3D and 4D scans, and better for the heart and thorax at the other centre. CONCLUSION: Diagnostic ultrasound cannot give a complete assessment of foetal anatomy. Autopsy examination is always strongly recommended for accurate genetic counselling. As already reported, 3D and 4D ultrasound may improve ultrasound performance in facial anomalies.

Keywords
  • Abnormalities, Multiple/pathology/ultrasonography
  • Autopsy
  • Female
  • Gestational Age
  • Humans
  • Pregnancy
  • Pregnancy Outcome
  • Referral and Consultation
  • Retrospective Studies
  • Sensitivity and Specificity
  • Ultrasonography, Prenatal
Citation (ISO format)
PICONE, Olivier et al. Correlation between referral ultrasound with suspected foetal anomalies and autopsy examination in two prenatal diagnosis centres. Impact of the routine use of 3D/4D scan. In: Prenatal diagnosis, 2008, vol. 28, n° 3, p. 191–196. doi: 10.1002/pd.1952
Main files (1)
Article (Accepted version)
accessLevelRestricted
Identifiers
ISSN of the journal0197-3851
475views
0downloads

Technical informations

Creation29/05/2009 11:36:00
First validation29/05/2009 11:36:00
Update time14/03/2023 15:05:58
Status update14/03/2023 15:05:58
Last indexation15/01/2024 18:30:48
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack