Performance and usability of cardiometabolic point of care devices in Nepal : A prospective, quantitative, accuracy study

Published inPLOS global public health, vol. 4, no. 10, e0003760
Publication date2024-10-03
First online date2024-10-03
Abstract

Non-communicable diseases (NCDs), such as cardiovascular disease and diabetes, represent a serious global health concern. There is an urgent need for prompt diagnosis and effective monitoring at point of care, especially in low- and middle-income countries. Here we present the results of a study assessing the quantitative accuracy of two devices that may fit the target product profile for a cardiometabolic point-of-care device. This prospective, quantitative, accuracy study (NCT05257564) was conducted between March to May 2022, investigating the performance of the JanaCare Aina Blood Monitoring System (JCAina) and the Tascom SimplexTAS 101 device (TAS101) compared with local standard laboratory methods in rural Nepal. Using fingerstick capillary blood, cardiometabolic parameters were analysed using both devices. The quantitative accuracy was compared against a local laboratory reference assay. System usability was also assessed. For JCAina, the mean absolute biases (Bland-Altman analysis) for glucose, HbA1c and total cholesterol tests were -3.87 mg/dL (95% CI: -7.52–-0.22), 1.34% (95% CI: 1.21–1.47), and -9.52 mg/dL (95% CI: -11.9–-7.2), respectively, corresponding to mean percentage biases of 2.0%, 18.5%, and -6.4%. These indicate clinically small (<10% biases) differences from laboratory results for glucose and cholesterol, and a moderate (10–20%) positive bias for HbA1c. For TAS101, the mean absolute biases for glucose, HbA1c, total cholesterol and creatinine tests were 18.7 mg/dL (95% CI: 15.8–21.5), -0.2% (95% CI: -0.26–-0.14), 29.8 mg/dL (95% CI: 27.0–32.6), and -0.02 mg/dL (95% CI: -0.05–0.01), respectively, corresponding to mean percentage biases of 12.1%, -2.6%, 15.8%, and -4.5%. These indicate clinically small differences for HbA1c and creatinine, and moderate positive biases for glucose and cholesterol. Both systems exhibited usability challenges. The JCAina and TAS101 point-of-care cardiometabolic devices were shown to have promising accuracy in environmental conditions such as in Nepal, though improvements are still needed for some parameters and for ease of use.

Trial registration: NCT05257564 (ClinicalTrials.gov).

Funding
  • International Committee of the Red Cross [ICR-NCDS01]
  • German Federal Ministry of Education and Research [KFW-TBBU02]
Citation (ISO format)
GIACHINO, Marina et al. Performance and usability of cardiometabolic point of care devices in Nepal : A prospective, quantitative, accuracy study. In: PLOS global public health, 2024, vol. 4, n° 10, p. e0003760. doi: 10.1371/journal.pgph.0003760
Main files (1)
Article (Published version)
Secondary files (2)
Supplemental data
accessLevelPublic
Supplemental data
accessLevelPublic
Identifiers
Additional URL for this publicationhttps://dx.plos.org/10.1371/journal.pgph.0003760
Journal ISSN2767-3375
76views
347downloads

Technical informations

Creation06/10/2024 08:41:36
First validation30/10/2024 10:53:11
Update30/10/2024 10:53:11
Status update30/10/2024 10:53:11
Last indexation30/10/2024 10:53:52
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack