Abstract

Background: Whether ultrathin-strut stents are particularly beneficial for lesions requiring implantation of more than 1 stent is unknown.

Methods: In a post-hoc lesion-level analysis of 2 randomized trials comparing ultrathin-strut biodegradable polymer Sirolimus-eluting stents (BP-SES) vs thin-strut durable polymer Everolimus-eluting stents (DP-EES), lesions were stratified into multistent lesions (MSL) vs single-stent lesions (SSL). The primary endpoint was target lesion failure (TLF), a composite of lesion-related unclear/cardiac death, myocardial infarction (MI), or revascularization, at 24 months.

Results: Among 5328 lesions in 3397 patients, 1492 (28%) were MSL (722 with BP-SES, 770 with DP-EES). At 2 years, TLF occurred in 63 lesions (8.9%) treated with BP-SES and 60 lesions (7.9%) treated with DP-EES in the MSL-group (subdistibution hazard ratio [SHR], 1.13; 95% CI, 0.77-1.64; P = .53), and in 121 (6.4%) and 136 (7.4%) lesions treated with BP-SES and DP-EES respectively (SHR, 0.86; 95% CI, 0.62-1.18; P = .35) in the SSL-group (P for interaction = .241). While the rates of lesion-related MI or revascularization were significantly lower in SSL treated with BP-SES as compared to DP-EES (3.5% vs 5.2%; SHR, 0.67; 95% CI 0.46-0.97; P = .036), no significant difference was observed in MSL (7.1% vs 5.4%; SHR, 1.31; 95% CI 0.85-2.03; P = .216) with significant interaction between groups (P for interaction = .014).

Conclusions: Rates of TLF are similar between ultrathin-strut BP-SES and thin-strut DP-EES in MSL and SSL. The use of ultrathin-strut BP-SES vs thin-strut DP-EES did not prove to be particularly beneficial for the treatment of multistent lesions.

Keywords
  • Humans
  • Absorbable Implants
  • Coronary Artery Disease / surgery
  • Drug-Eluting Stents
  • Everolimus / pharmacology
  • Myocardial Infarction / epidemiology
  • Percutaneous Coronary Intervention
  • Polymers
  • Prosthesis Design
  • Randomized Controlled Trials as Topic
  • Sirolimus
  • Treatment Outcome
Citation (ISO format)
HÄNER, Jonas D et al. Ultrathin-strut vs thin-strut drug-eluting stents for multi and single-stent lesions : A lesion-level subgroup analysis of 2 randomized trials. In: The American heart journal, 2023, vol. 263, p. 73–84. doi: 10.1016/j.ahj.2023.05.004
Main files (1)
Article (Published version)
Identifiers
Journal ISSN0002-8703
67views
134downloads

Technical informations

Creation02/07/2024 14:26:53
First validation24/07/2024 06:57:49
Update24/03/2026 14:22:25
Status update24/03/2026 14:22:25
Last indexation24/03/2026 14:24:37
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack