en
Scientific article
English

Implant-supported single all-ceramic crowns made from prefabricated (stock) or individualized CAD/CAM zirconia abutments : A 5 year randomized clinical trial

Published inJournal of esthetic and restorative dentistry, vol. 36, no. 1, p. 164-173
Publication date2024-01
First online date2024-01-03
Abstract

Aim: The aim of this randomized, prospective, and clinical multicenter study was to compare the overall clinical performance of two restorative options over a 5-year period: individualized CAD/CAM abutments veneered with a hand-layered ceramic, and prefabricated zirconium dioxide abutments veneered with press ceramic and inserted into a single edentulous gap in the anterior maxilla.

Materials and methods: Forty subjects were recruited from two universities: 20 from the University of XX and 20 from the University of XY. Each subject received an implant to restore a single edentulous gap in the maxillary anterior region (14-24 FDI). 20 patients were randomized into each Group. Group A received a one-piece single crown produced from a prefabricated zirconia abutment with pressed ceramic and Group B received an individualized CAD/CAM zirconia abutment with a hand-layered technique. After 5 years, the aesthetic and radiographic parameters were assessed.

Results: Group A had four dropouts and one failure, resulting in a 95% survival rate and 95% success rate. Group B had two dropouts and two failures which resulted in a 90% survival rate and 90% success rate. No crestal bone level changes were observed, with a mean DIB of 0.06 mm in Group A and 0.09 mm in Group B. No statistically significant differences were present at baseline, 6 months, 1 year, 3 years, or 5 years for DIB values between time points and groups. Pink aesthetic score/white aesthetic score, Peri-Implant and Crown Index, and Implant Crown Aesthetic Index values were stable over time at all five points for both groups.

Conclusion: Both implant-supported restorative options represent a valuable treatment option for the restoration of implant crowns in the anterior maxilla.

Clinical significance: In general, the use of ceramic abutments in the anterior zone represents a valuable treatment procedure with both standardized and CAD/CAM individualized abutments and following the recommendations from the respective manufacturer(s).

eng
Keywords
  • CAD/CAM
  • Ceramics
  • Dental materials
  • Implants
  • Prosthodontics
  • Humans
  • Prospective Studies
  • Zirconium
  • Crowns
  • Computer-Aided Design
  • Dental Abutments
  • Titanium
Citation (ISO format)
WITTNEBEN, Julia-Gabriela et al. Implant-supported single all-ceramic crowns made from prefabricated (stock) or individualized CAD/CAM zirconia abutments : A 5 year randomized clinical trial. In: Journal of esthetic and restorative dentistry, 2024, vol. 36, n° 1, p. 164–173. doi: 10.1111/jerd.13188
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
ISSN of the journal1496-4155
20views
0downloads

Technical informations

Creation06/20/2024 12:06:03 PM
First validation06/21/2024 6:51:10 AM
Update time06/21/2024 6:51:10 AM
Status update06/21/2024 6:51:10 AM
Last indexation06/21/2024 6:51:30 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack