Scientific article
OA Policy
English

Effect of internal connection type and screw channel angle on the screw stability of anterior implant-supported zirconia crowns

Published inClinical oral implants research, vol. 34, no. 11, p. 1248-1256
Publication date2023-11
First online date2023-08-14
Abstract

Objectives: To investigate the effect of implant-abutment connection and screw channel angle on screw stability by comparing a newly introduced and an established connection, before and after cyclic loading.

Materials and methods: Implants (N = 44) with Torcfit (TF) or Crossfit (CF) connection were divided to be restored with a straight (CFS and TFS) or an angled screw access channel (CFA and TFA) titanium-base abutment (n = 11). CFA and TFA received screw-retained crowns, whereas CFS and TFS received hybrid zirconia abutments and cement-retained crowns. The initial torque value (ITV) of each complex (ITVI) and removal torque value (RTV) after 24 h (RTVI) were measured. Screws were replaced with new ones, ITVs were recorded again (ITVF), and crowns were cyclically loaded (2.4 million cycles, 98 N) to measure RTVs again (RTVF). Percentage torque loss was calculated. Data were analyzed (α = 0.05).

Results: ITVs were similar among groups (p ≥ .089). CF led to higher RTVs (p ≤ .002), while CFS had higher RTVIthan CFA (p = .023). After 24 h, CFS had lower percentage torque loss than TF, while CFA had lower percentage torque loss than TFA (p ≤ .011). After cyclic loading, CF led to lower percentage torque (p < .001).

Conclusion: The implant-abutment connection affected the removal torque values. However, no screw loosening occurred during cyclic loading, which indicated a stable connection for all groups. Screw access channel angle did not affect screw stability after cyclic loading.

Keywords
  • Angled screw channel
  • Implant-abutment connection
  • Screw stability
  • Torque loss
  • Dental Stress Analysis
  • Dental Cements
  • Crowns
  • Bone Screws
  • Torque
  • Titanium
  • Dental Abutments
  • Dental Implant-Abutment Design
  • Dental Implants
  • Materials Testing
Citation (ISO format)
ÇAKMAK, Gülce et al. Effect of internal connection type and screw channel angle on the screw stability of anterior implant-supported zirconia crowns. In: Clinical oral implants research, 2023, vol. 34, n° 11, p. 1248–1256. doi: 10.1111/clr.14165
Main files (1)
Article (Published version)
Identifiers
ISSN of the journal0905-7161
29views
5downloads

Technical informations

Creation17/01/2024 15:06:47
First validation22/01/2024 14:38:13
Update time22/01/2024 14:38:13
Status update22/01/2024 14:38:13
Last indexation06/10/2024 22:52:45
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack