Proton-decoupled phosphorus-31 magnetic resonance spectroscopy in the evaluation of native and well-functioning transplanted kidneys

Published inAcademic radiology, vol. 3, no. 12, p. 1030-1037
Publication date1996-12
Abstract

Rationale and objectives: To evaluate whether decoupling improves signal-to-noise ratio and frequency resolution of in vivo kidney spectra, and to compare native and well-functioning transplant kidneys.

Methods: Proton decoupling in conjunction with three-dimensional chemical shift imaging (3D-CSI) in phosphorus-31 magnetic resonance (MR) spectroscopy was used with a spatial resolution of 64 cm3 and 17-minute acquisition time to compare native (n = 10) and well-functioning transplant (n = 9) kidneys.

Results: Proton decoupling improved peak amplitudes by almost 30%, as well as chemical shift resolution of in vivo kidney spectra. No statistically significant differences in phosphometabolite ratios and renal spectra were observed between healthy volunteers and patients with nonrejecting transplants. The phosphodiester-phosphomonoester ratio was 3.02 +/- 0.88, phosphomonoester-inorganic phosphate ratio was 1.07 +/- 0.44, and inorganic phosphate-adenosine triphosphate ratio was 0.58 +/- 0.22 after correction for saturation effects.

Conclusion: Improved spectra of native and transplant kidneys can be obtained in vivo with MR spectroscopy by using a short acquisition time.

Keywords
  • Adenosine Triphosphate / analysis
  • Adult
  • Glycerylphosphorylcholine / analysis
  • Humans
  • Image Enhancement / methods
  • Kidney / metabolism
  • Kidney Transplantation / physiology
  • Magnetic Resonance Spectroscopy / instrumentation
  • Magnetic Resonance Spectroscopy / methods
  • Male
  • Middle Aged
  • Organophosphates / analysis
  • Phosphates / analysis
  • Phosphatidylethanolamines / analysis
  • Phosphocreatine / analysis
  • Phosphorus / analysis
  • Protons
  • Signal Processing, Computer-Assisted
Affiliation entities Not a UNIGE publication
Citation (ISO format)
VALLÉE, Jean-Paul et al. Proton-decoupled phosphorus-31 magnetic resonance spectroscopy in the evaluation of native and well-functioning transplanted kidneys. In: Academic radiology, 1996, vol. 3, n° 12, p. 1030–1037. doi: 10.1016/s1076-6332(96)80040-7
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN1076-6332
55views
0downloads

Technical informations

Creation05/09/2022 08:26:11
First validation19/04/2023 13:40:35
Update19/04/2023 13:40:35
Status update19/04/2023 13:40:35
Last indexation01/11/2024 04:50:05
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack