Scientific article
English

Estimation of myocardial blood flow for longitudinal studies with 13N-labeled ammonia and positron emission tomography

Published inJournal of nuclear cardiology, vol. 3, no. 6, p. 494-507
Publication date1996-11
Abstract

BACKGROUND: Although several modeling strategies have been developed and validated for quantification of myocardial blood flow (MBF) from 13N-labeled ammonia positron emission tomographic data, a comparison of noise characteristics of the various techniques in serial studies is lacking.

METHODS AND RESULTS: Dynamic 13N-labeled ammonia positron emission tomographic imaging was performed at baseline and after pharmacologic stress in (1) single studies of four dogs with concomitant measurement of microsphere blood flow and (2) initial and follow-up studies of eight normal volunteers. Data were obtained from short-axis images for the blood pool and myocardial regions corresponding to the three arterial vascular territories. Indexes of MBF were obtained by four distinct techniques: (1) University of California, Los Angeles, two-compartment model, (2) Michigan two-compartment model, and (3) a one-compartment model with variable blood volume term. Coronary flow reserve (CFR) was measured as the ratio of stress/rest MBF. The estimated standard deviation of the measurement error for the relative change between studies of rest and stress MBF and CFR was determined for each technique. Estimates of MBF from all techniques showed good correlation with microsphere blood flow (r = 0.95 to 0.96) in canine myocardium. In human studies, similar mean estimates of MBF were found with all techniques. Techniques 1 and 3 showed the smallest interstudy variability in MBF and CFR. The estimated standard deviations for these techniques were approximately 20%, 30%, and 27% for rest MBF, stress MBF, and CFR, respectively.

CONCLUSION: Noninvasive quantification of MBF and CFR from dynamic 13N-labeled ammonia positron emission tomography is most reproducible with technique 1 or 3. The ability to account for differences in myocardial partial volume gives preference to technique 3. However, substantial interstudy variability in regional MBF remains, suggesting the importance of procedural factors or real temporal fluctuations in MBF.

Keywords
  • Computer-Assisted Male Middle Aged Models
  • Cardiovascular Nitrogen Radioisotopes Reproducibility of Results Tomography
  • Emission-Computed
  • Ammonia
  • Animals
  • Coronary Circulation / physiology
  • Dogs
  • Heart / diagnostic imaging
  • Humans
  • Image Processing, Computer-Assisted
  • Male
  • Middle Aged
  • Models, Cardiovascular
  • Nitrogen Radioisotopes
  • Reproducibility of Results
  • Tomography, Emission-Computed
  • Myocardial blood flow
  • PET
  • N-13 ammonia
  • Compartmental modeling
Affiliation entities Not a UNIGE publication
Citation (ISO format)
DEGRADO, T et al. Estimation of myocardial blood flow for longitudinal studies with 13N-labeled ammonia and positron emission tomography. In: Journal of nuclear cardiology, 1996, vol. 3, n° 6, p. 494–507. doi: 10.1016/s1071-3581(96)90059-8
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN1071-3581
84views
0downloads

Technical informations

Creation05/09/2022 08:14:27
First validation22/03/2023 14:50:50
Update22/03/2023 14:50:50
Status update22/03/2023 14:50:50
Last indexation01/11/2024 04:34:19
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack