Scientific article
OA Policy
English

Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures

Publication date2022-05-27
First online date2022-05-27
Abstract

Statement of problem: Three-dimensional printing has facilitated the fabrication processes in dentistry. However, knowledge on the effect of layer thickness on the trueness of 3D-printed fixed partial dentures (FPDs) is lacking.

Purpose: The purpose of this in vitro study was to compare the effect of printing layer thickness on the trueness of 3-unit interim FPDs fabricated by using additive manufacturing with that of those fabricated by subtractive manufacturing.

Material and methods: The right first premolar and first molar teeth of a dentate mandibular model were prepared for a 3-unit restoration and then digitized by using an intraoral scanner. A 3-unit interim FPD was designed to fabricate 40 restorations by using either the additive (NextDent C&B MFH) with layer thicknesses of 20 μm (n=10), 50 μm (n=10), and 100 μm (n=10) or subtractive manufacturing technique (Upcera) (milled, n=10). After fabrication, the interim FPDs were digitized by using the same intraoral scanner and were superimposed over the design data by using a 3D analysis software program. Root mean square (RMS) was used to analyze the trueness of the restorations at 4 different surfaces (external, intaglio, marginal area, and intaglio occlusal) and as a complete unit (overall). Data were analyzed with the Kruskal-Wallis and Wilcoxon tests with Bonferroni correction (α=.05).

Results: The 100-μm-layer thickness interim FPDs showed the greatest overall (P≤.015), external (P≤.021), and intaglio occlusal (P≤.021) deviations, whereas the milled interim FPDs showed the lowest (P=.001). No significant differences were found among the test groups for marginal RMS (P≥.108). The differences between the 50-μm-layer thickness and 100-μm-layer thickness interim FPDs for the intaglio surface deviations (P=.064) and between the 20-μm-layer thickness and 50-μm-layer thickness interim FPDs for each surface tested were not statistically significant (P≥.108).

Conclusions: The printing layer thickness had a significant effect on the trueness of the additively manufactured interim FPDs. However, subtractively manufactured interim FPDs presented higher trueness than those additively manufactured, regardless of the printing layer thickness.

Citation (ISO format)
ÇAKMAK, Gülce et al. Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures. In: The Journal of prosthetic dentistry, 2022. doi: 10.1016/j.prosdent.2022.04.015
Main files (1)
Article (Published version)
Identifiers
Journal ISSN0022-3913
109views
393downloads

Technical informations

Creation14/02/2023 10:32:00
First validation14/02/2023 10:32:00
Update25/03/2026 08:32:04
Status update25/03/2026 08:32:04
Last indexation25/03/2026 08:37:50
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack