Scientific article
OA Policy
English

Superparamagnetic iron oxide particles and positive enhancement for myocardial perfusion studies assessed by subsecond T1-weighted MRI

Published inMagnetic resonance imaging, vol. 11, no. 8, p. 1139-1145
Publication date1993
Abstract

Superparamagnetic iron oxide particles (SPIOs) are usually referred to as T2 MR contrast agents, reducing signal intensity (SI) on T2-weighted MR images (negative enhancement). This study reports the original use of SPIOs as T1-enhancing contrast agents, primarily assessed in vitro, and then applied to an in vivo investigation of a myocardial perfusion defect. Using a strongly T1-weighted subsecond MR sequence with SPIOs intravenous (IV) bolus injection, MR imaging of myocardial vascularization after reperfusion was performed, on a dog model of coronary occlusion followed by reperfusion. Immediately after the intravenous bolus injection of 20 mumol/kg of SPIOs, a positive signal intensity enhancement was observed respectively, in the right and left ventricular cavity and in the nonischemic left myocardium. Moreover, compared to normal myocardium, the remaining ischemic myocardial region (anterior wall of the left ventricle) appeared as a lower and delayed SI enhancing area (cold spot). Mean peak SIE in the nonischemic myocardium (posterior wall) was significantly higher than in the ischemic myocardium (anterior wall) (110 +/- 23% vs. 74 +/- 22%, Mann-Whitney test alpha < 1%, n1 = 6, n2-n1 = 0, U > 2). In conclusion, the T1 effect of SPIOs at low dose, during their first intravascular distribution, suggests their potential use as positive markers to investigate the regional myocardial blood flow and some perfusion defects such as the "no-reflow phenomenon

Keywords
  • Animals
  • Contrast Media
  • Dextrans
  • Dogs
  • Ferrosoferric Oxide
  • Image Processing, Computer-Assisted
  • Iron
  • Magnetic Resonance Imaging / methods
  • Magnetite Nanoparticles
  • Myocardial Ischemia / diagnosis
  • Myocardium / pathology
  • Oxides
Citation (ISO format)
CARNET, Emmanuelle et al. Superparamagnetic iron oxide particles and positive enhancement for myocardial perfusion studies assessed by subsecond T1-weighted MRI. In: Magnetic resonance imaging, 1993, vol. 11, n° 8, p. 1139–1145. doi: 10.1016/0730-725x(93)90241-5
Main files (1)
Article (Published version)
accessLevelPublic
Identifiers
Journal ISSN0730-725X
77views
85downloads

Technical informations

Creation05/09/2022 07:16:00
First validation05/09/2022 07:16:00
Update time16/03/2023 10:25:23
Status update16/03/2023 10:25:22
Last indexation01/11/2024 03:54:15
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack