Zirconia cantilever fixed dental prostheses supported by one or two implants: an in vitro study on mechanical stability and technical outcomes

Published inThe international journal of oral & maxillofacial implants, vol. 37, no. 4, p. 748-755
Publication date2022
Abstract

Purpose: To evaluate the mechanical stability of highly translucent zirconia (Zr) cantilevered fixed dental prostheses (cFDPs) and to investigate the influence of the number of implants (one versus two) supporting cFDPs with different restorative materials on their mechanical stability and load-bearing capacity.

Materials and methods: Thirty-two specimens consisting of implant-supported prostheses embedded in resin blocks were fabricated. Sixteen specimens received one implant (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) to support two-unit cement-retained cFDPs with one extension unit and the other 16 received two implants (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) positioned corresponding to the missing maxillary central incisors to support three-unit cement-retained cFDPs with one extension unit. Two different prosthetic materials, chromium-cobalt (Cr-Co; Wirobond C+, Bego) and highly translucent Zr (Lava Plus, 3M ESPE) were selected to fabricate the two- and three-unit cFDPs. Standardized twoand three-unit Cr-Co frameworks (CC-I, n = 8; CC-II, n = 8) and highly translucent Zr frameworks (Zr-I, n = 8; Zr-II, n = 8) with a 6-mm cantilever extension were fabricated using CAD/CAM (EOS M 290). Following thermomechanical fatigue loading, the specimens were tested for fracture resistance under static loading. The influence of restoration material and number of supporting implants on fracture resistance were tested using two-way analysis of variance (ANOVA). The level of statistical significance was set below 5% (α < .05).

Results: All specimens survived aging. The mean (± standard deviation) fracture resistance values were 416.25 (± 42.71) N for Zr-I, 548.75 (± 75.41) N for Zr-II, 601.0 (± 41.51) N for CC-I, and 664.5 (± 37.59) N for CC-II. CC and Zr group specimens showed significantly different fracture resistance results (P < .001). The number of implants significantly influenced the fracture resistance of Zr groups (P = .001), whereas the influence was not significant for CC groups (P = .089).

Conclusion: Within the limitations of this in vitro study, highly translucent zirconia cFDP frameworks demonstrated the potential to withstand reported physiologic occlusal forces applied in the anterior region. The increase in the number of implants supporting zirconia cFDPs significantly contributed to achieving higher fracture resistance values.

Keywords
  • Computer-Aided Design
  • Dental Abutments
  • Dental Implants
  • Dental Materials / chemistry
  • Dental Prosthesis, Implant-Supported
  • Dental Restoration Failure
  • Dental Stress Analysis
  • Materials Testing
  • Zirconium / chemistry
Citation (ISO format)
KARASAN, Duygu et al. Zirconia cantilever fixed dental prostheses supported by one or two implants: an in vitro study on mechanical stability and technical outcomes. In: The international journal of oral & maxillofacial implants, 2022, vol. 37, n° 4, p. 748–755. doi: 10.11607/jomi.8953
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN0882-2786
212views
2downloads

Technical informations

Creation11/29/2022 11:46:00 AM
First validation11/29/2022 11:46:00 AM
Update time03/16/2023 10:07:48 AM
Status update03/16/2023 10:07:47 AM
Last indexation11/01/2024 4:36:38 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack