Scientific article
OA Policy
English

Detection of distant metastases and distant second primary cancers in head and neck squamous cell carcinoma: comparison of [18F]FDG PET/MRI and [18F]FDG PET/CT

Published inInsights into imaging, vol. 13, no. 1, 121
Publication date2022-07-28
First online date2022-07-28
Abstract

Purpose: This prospective study aimed to compare the diagnostic performance of [18]FDG PET/MRI and PET/CT for the detection of distant metastases and distant second primary cancers in patients with head and neck squamous cell carcinoma (HNSCC).

Methods: A total of 103 [18F]FDG PET/MRI examinations immediately followed by PET/CT were obtained in 82 consecutive patients for staging of primary HNSCC (n = 38), suspected loco-regional recurrence/follow-up (n = 41) or unknown primary HNSCC (n = 3). Histology and follow-up > 2 years formed the standard of reference. Blinded readers evaluated the anonymized PET/MRI and PET/CT examinations separately using a 5-point Likert score. Statistical analysis included: receiver operating characteristic (ROC) analysis, jackknife alternative free-response ROC (JAFROC) and region-of-interest (ROI)-based ROC to account for data clustering and sensitivity/specificity/accuracy comparisons for a score ≥ 3.

Results: Distant metastases and distant second primary cancers were present in 23/103 (22%) examinations in 16/82 (19.5%) patients, and they were more common in the post-treatment group (11/41, 27%) than in the primary HNSCC group (3/38, 8%), p = 0.039. The area under the curve (AUC) per patient/examination/lesion was 0.947 [0.927-1]/0.965 [0.917-1]/0.957 [0.928-0.987] for PET/MRI and 0.975 [0.950-1]/0.968 [0.920-1]/0.944 [0.910-0.979] for PET/CT, respectively (p > 0.05). The diagnostic performance of PET/MRI and PET/CT was similar according to JAFROC (p = 0.919) and ROI-based ROC analysis (p = 0.574). Sensitivity/specificity/accuracy for PET/MRI and PET/CT for a score ≥ 3 was 94%/88%/89% and 94%/91%/91% per patient, 96%/90%/91% and 96%/93%/93% per examination and 95%/85%/90% and 90%/86%/88% per lesion, respectively, p > 0.05.

Conclusions: In HNSCC patients, PET/MRI and PET/CT had a high and similar diagnostic performance for detecting distant metastases and distant second primary cancers.

Keywords
  • Head and neck tumors
  • Metastases
  • PET/CT
  • PET/MRI
  • Second primary cancer
Citation (ISO format)
KATIRTZIDOU, Eirini et al. Detection of distant metastases and distant second primary cancers in head and neck squamous cell carcinoma: comparison of [18F]FDG PET/MRI and [18F]FDG PET/CT. In: Insights into imaging, 2022, vol. 13, n° 1, p. 121. doi: 10.1186/s13244-022-01261-0
Main files (1)
Article (Published version)
Identifiers
Journal ISSN1869-4101
241views
312downloads

Technical informations

Creation24/08/2022 12:42:00
First validation24/08/2022 12:42:00
Update07/01/2026 15:12:33
Status update07/01/2026 15:12:33
Last indexation07/01/2026 15:12:35
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack