en
Scientific article
Open access
English

His-optimized cardiac resynchronization therapy with ventricular fusion pacing for electrical resynchronization in heart failure

Published inJACC. Clinical electrophysiology, vol. 7, no. 7, p. 881-892
Publication date2021-07
First online date2021-02-24
Abstract

This study sought to evaluate the effectiveness of His-optimized cardiac resynchronization therapy (HOT-CRT) for reducing left ventricular activation time (LVAT) compared to His bundle pacing (HBP) and biventricular(BiV) pacing (including multipoint pacing [MPP]), using electrocardiographic (ECG) imaging.

HBP may correct bundle branch block (BBB) and has shown encouraging results for providing CRT. However, HBP does not correct BBB in all patients and may be combined with univentricular or BiV fusion pacing to deliver HOT-CRT to maximize resynchronization.

Nineteen patients with a standard indication for CRT, implanted with HBP without correction of BBB and BiV (n=14) or right ventricular (n=5) leads, were prospectively enrolled. Patients underwent ECG imaging while pacing in different configurations using different LV electrodes and at different HBP ventricular pacing (VP) delays. The primary endpoint was reduction in LVAT with HOT-CRT, and the secondary endpoints included various other dys-synchrony measurements including right ventricular activation time (RVAT).

Compared to HBP, HOT-CRT reduced LVAT by 21% (−17 ms [95% confidence interval [CI]: −25 to −9 ms]; p < 0.001) and outperformed BiV by 24% (−22 ms [95% CI: −33 to −10 ms]; p = 0.002) and MPP by 13% (−11 ms [95% CI: −21 to −1 ms]; p = 0.035). Relative to HBP, HOT-CRT also reduced RVAT by 7% (−5 ms [95% CI: −9 to −1 ms; p = 0.035) in patients with right BBB, whereas RVAT was increased by BiV. The other electrical dyssynchrony measurements also improved with HOT-CRT.

HOT-CRT acutely improves ventricular electrical synchrony beyond BiV and MPP. The impact of this finding needs to be evaluated further in studies with clinical follow-up. (Electrical Resynchronization and Acute Hemodynamic Effects of Direct His Bundle Pacing Compared to Biventricular Pacing; NCT03452462).

eng
Keywords
  • His bundle pacing
  • His-optimized CRT
  • Biventricular pacing
  • Cardiac resynchronization therapy
  • Eelectrocardiographic imaging
  • Ventricular activation times
  • Bundle-Branch Block / therapy
  • Cardiac Resynchronization Therapy
  • Heart Failure / therapy
  • Heart Ventricles / diagnostic imaging
  • Humans
  • Treatment Outcome
Funding
  • SNSF - [ME11709]
Citation (ISO format)
ZWEERINK, Alwin et al. His-optimized cardiac resynchronization therapy with ventricular fusion pacing for electrical resynchronization in heart failure. In: JACC. Clinical electrophysiology, 2021, vol. 7, n° 7, p. 881–892. doi: 10.1016/j.jacep.2020.11.029
Main files (1)
Article (Published version)
Secondary files (1)
Identifiers
ISSN of the journal2405-500X
110views
38downloads

Technical informations

Creation02/21/2022 3:35:00 PM
First validation02/21/2022 3:35:00 PM
Update time03/16/2023 6:53:22 AM
Status update03/16/2023 6:53:21 AM
Last indexation02/12/2024 1:40:54 PM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack