Scientific article
OA Policy
English

Influence of customized over-scan body rings on the intraoral scanning effectiveness of a multiple implant edentulous mandibular model

Published inJournal of dentistry, vol. 122, 104095
Publication date2022-07
Abstract

Objectives: To evaluate the effectiveness of intraoral scanning with identical multiple implant scan bodies (ISB) using customized over scan body rings (COR) as an auxiliary system.

Methods: Six printed rings with different diameters and shapes were attached at different levels to each identical ISB of an edentulous mandibular master model. The master model was scanned using an intraoral scanner (Primescan CEREC) until valid digital models for the COR group (n=10) and for the unmodified ISB (UN) group (n=10) were obtained. The total scanning times and the number of rescans required was registered. To assess differences between scanning efficiency the Student T-test and Mann Whitney U-Test were applied. A Coordinate Measuring Machine (CMM) was used to register the reference model. To evaluate accuracy discrepancies between the test scans (n=20) and the reference model, Geomagic Control X was used. Mann Whitney U-test was applied to calculate statistically significant differences.

Results: To achieve a valid model, an average of 4.70 rescans / repetitions were required for the UN group, whereas for the COR group required an average of 1.40 rescans (p<.001). Mean total scanning time was 201.10 s and 542.40 s for the COR and UN group, respectively (p=.001). No statistically significant differences were found between the groups in terms of accuracy (p>.05) with respectively COR and UN values; mean linear trueness 34.38 μm and 31.14 μm, mean linear precision 22.94 μm and 18.51 μm, mean angular trueness 0.12° and 0.14°, mean angular precision 0.075° and 0.08°.

Conclusion: The use of the COR system may increase the scanning efficiency of multiple implants with similar ISBs without impacting the accuracy.

Keywords
  • 3D printing
  • Accuracy
  • Complete arch
  • Intraoral scanner
  • Scan body
  • Scanning time
Citation (ISO format)
GARCÍA-MARTÍNEZ, Irene et al. Influence of customized over-scan body rings on the intraoral scanning effectiveness of a multiple implant edentulous mandibular model. In: Journal of dentistry, 2022, vol. 122, p. 104095. doi: 10.1016/j.jdent.2022.104095
Main files (1)
Article (Published version)
Identifiers
Journal ISSN0300-5712
148views
282downloads

Technical informations

Creation15/06/2022 10:25:00
First validation15/06/2022 10:25:00
Update16/03/2023 06:49:35
Status update16/03/2023 06:49:34
Last indexation01/11/2024 02:00:16
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack