Scientific article
OA Policy
English

One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries

Published inCoronary artery disease, vol. 32, no. 5, p. 391-396
Publication date2021-08-01
Abstract

Objectives: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. Methods: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. Results: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). Conclusions: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.

Keywords
  • Aged
  • Biocompatible Materials / pharmacology
  • Chromium Alloys / pharmacology
  • Coronary Artery Disease / surgery
  • Coronary Restenosis / diagnosis
  • Coronary Restenosis / etiology
  • Coronary Restenosis / mortality
  • Drug-Eluting Stents / adverse effects
  • Drug-Eluting Stents / classification
  • Equipment Failure Analysis
  • Female
  • Humans
  • Immunosuppressive Agents / pharmacology
  • Male
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation
  • Percutaneous Coronary Intervention / methods
  • Postoperative Complications / diagnosis
  • Postoperative Complications / etiology
  • Postoperative Complications / mortality
  • Prosthesis Design
  • Registries / statistics & numerical data
  • Sirolimus / analogs & derivatives
  • Sirolimus / pharmacology
  • Survival Analysis
Citation (ISO format)
VLIEGER, Selina et al. One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries. In: Coronary artery disease, 2021, vol. 32, n° 5, p. 391–396. doi: 10.1097/MCA.0000000000000958
Main files (1)
Article (Published version)
Secondary files (1)
Identifiers
ISSN of the journal0954-6928
156views
52downloads

Technical informations

Creation21/02/2022 15:37:00
First validation21/02/2022 15:37:00
Update time16/03/2023 06:38:49
Status update16/03/2023 06:38:47
Last indexation01/10/2024 21:29:39
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack